Applications manual
For AME series
6.9.7
SYS_RESTORE_FACTORY_SETTING [1Eh] [09h] [01h] [1Fh]
SET_CC_CONTROL
:Control amount for constant current operation
SET_RAMP_RATE
:Output voltage change rate
SET_VOUT_LV_ALARM
:Output voltage to output alarm signal
SET_SELECTION_CH
Setting target
SYS_STORE_USER_SETTING Supported commands
Output module
(Set value: 1-6)
SET_VOUT
:Output voltage setting
SET_VOUT_UPPER_LIMIT
:Variable upper limit of output voltage
SET_VOUT_LOWER_LIMIT
:Variable lower limit of output voltage
SET_CC_MODE_ITRM
:Constant current setting mode
SET_CC_MODE_INFO
:Constant current setting mode
SET_CC
:Constant current operating value
SET_CC_UPPER_LIMIT
:Upper limit of constant current operating value
SET_VOUT_HV_ALARM
:Output voltage to output alarm signal
Do not transmit "SYS_STORE_USER_SETTING" command and this command continuously
within 5 seconds. If the process is not completed, this command is not accepted and an error is
returned. (Error code 4 : The state of the internal process is busy.)
This command stores settings of target module selected by "SET_SELECTION_CH" command in
non-volatile memory of each module.
This command needs to be executed to every target module individually.
Even if this command is sent, the setting will not return to the factory default while the input voltage
is being applied.
When the input voltage is turned off after transmitting this command, the factory default will be
restored after turning the input on.
The input should not be turned off for at least five seconds after this command is transmitted.
Otherwise, it may not properly be recorded in the nonvolatile memory.
Return value
1
Multiple items are stored at the same time.
However, the values set after transmitting this command will not be recorded.
The input should not be turned off for at least five seconds after this command is transmitted.
Otherwise, it may not properly be recorded in the non-volatile memory.
Return value
0
If the instruction is executed on an output module other than the corresponding output modules, an
error is returned. (Error code 6 : Command that do not correspond to the setting target)
Do not transmit "SYS_RESTORE_FACTORY_SETTING" command and this command
continuously within 5 seconds. If the process is not completed, this command is not accepted and
an error is returned. (Error code 4 : The state of the internal process is busy.)
This command restore values and settings in the non-volatile memory of the AME
stored by "SYS_STORE_USER_SETTING" command to the factory defaults.
44