Applications manual
For AME series
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
13
14
R
︓
Read command
W
︓
Write command
READ_RAMP_RATE_PRM
:Returns the current change rate of the output voltage.
R
SET_STOP_VIN_AC
:Setting a stopping voltage for AC input.
W
READ_STOP_VIN_AC_PRM
:Returning a stopping voltage for AC input.
R
SET_RAMP_RATE
:Setting a ramp rate of the output voltage.
W
:Returning a upper limit for the constant current adjustment
range.
R
6.4 Commands to set constant current
SET_CC_MODE_ITRM
:The constant current can be set by the voltage on the ITRM
terminal.
W
SET_CC_MODE_INFO
:The constant current can be set by the communication
function.
W
SET_CC_CONTROL
R
SET_CC_FACTORY_SETTING
:Restoring a factory default value of the constant current.
W
SET_CC_LIMIT_FACTORY_SETTING
:Restoring a factory default value of a upper limit for the
constant current.
W
READ_CC_REFERENCE
:Returning the controlling value for the constant current.
R
SET_CC_UPPER_LIMIT
:Setting a upper limit for the constant current adjustment range.
READ_CC_UPPER_LIMIT_PRM
R
SET_TOFF_DELAY_SLOT
:Setting a power-off delay time.
READ_CC_MODE_PRM
W
:Setting a controlled variable of the constant current.
W
W
READ_CC_PRM
:Returning a value of the constant current.
:Returning a controlled variable of the constant current.
R
6.5 Commands to set output voltage sequence
SET_TON_DELAY_SLOT
Table 6.1 Command outline (2/4)
W
READ_START_UP_VIN_AC_PRM
SET_CC
:Setting a value of the constant current.
:Returning a starting voltage for AC input.
R
SET_TON_DELAY_VIN
:Setting delay time for activation after AC input.
W
READ_TON_DELAY_VIN_PRM
:Returning delay time for activation after AC input.
:Returning a power-on delay time.
SET_TON_DELAY_FACTORY_SETTING
:Restoring a factory default value of the power-on delay time.
W
:Setting a power-on delay time.
W
READ_TON_DELAY_SLOT_PRM
:Returning a setting method of the constant current.
R
READ_CC_CONTROL_PRM
R
SET_TOFF_DELAY_FACTORY_SETTING
:Restoring a factory default value of the power-off delay time.
W
W
READ_TOFF_DELAY_SLOT_PRM
:Returning a power-off delay time.
R
SET_START_UP_VIN_AC
:Setting a starting voltage for AC input.
12
ver1.1E 2020.2.12