Applications manual
For AME series
6.8.6
TOTAL_OUTPUT_TIME
TOTAL_OUTPUT_TIME_1
[1Eh] [08h] [11h] [00h]
0
~
59
minute
Return value:57
⇒
57 minute
TOTAL_OUTPUT_TIME_2
[1Eh] [08h] [11h] [01h]
TOTAL_OUTPUT_TIME_3
[1Eh] [08h] [11h] [02h]
0
~
2
32
-1
hour
(
Theoretical value
)
Low 16 bits
:
TOTAL_INPUT_TIME_2
(
0~65,535hour
)
High 16 bits
:
TOTAL_INPUT_TIME_3
If the instruction is executed on an output module other than the corresponding output modules, an
error is returned.(Error code 6 : Command that do not correspond to the setting target)
This command returns the accumulated time for outputs stored in the non-volatile
memory of the AME.
If the front-end module is selected, the accumulated time for output of the front-end module is
returned.
If a slot is selected, the accumulated time for output of the output module is returned.
The returned value of "TOTAL_OUTPUT_TIME_1" represents "minute" and it is reset to "0" every
60 minutes.
The returned value of "TOTAL_OUTPUT_TIME_2" represents low 16 bits and the one of
"TOTAL_OUTPUT_TIME_3" represents high 16 bits. And, those 32 bits are returned as the
accumulated time for the application of the input voltage, in hour.
The data may not be stored for less than one minute before power-off.
Constitution
Range
Example of return value
Range