Viper Service Manual
© 2008-2012, IMI Cornelius Inc.
- 73 -
Publication Number: 621260373SER
Figure 52. View of Syrup Pressure Switch and Valve
W
ATER
P
RESSURE
S
WITCH
R
EPLACEMENT
The water pressure switch, shown in Figure 53, is located in back of the water fil-
ter, when viewed from the rear of the unit. Access to the switch is obtained by
removing the left side panel of the unit, when viewed from the rear. To replace
the water pressure switch, perform the procedure in Table 57..
Table 56.
Step
Action
1
Disconnect power to the unit
2
Remove the appropriate side panel.
3
Turn off the syrup supply to the unit.
4
Drain the syrup from the system.
5
Disconnect the wires on the pressure switch.
6
Remove the switch, using two wrenches.
7
Replace the switch with a new unit.
8
Reverse the procedure to install the new switch.
9
Restore the syrup supply and check for leaks.
10
Check switch operation.