When replacing or testing electronic components, be sure to wear a static strap
that is connected to a chassis ground. This protects the electronic components
from any static charge while working on the unit.
The control board is located in the E-Box. It is mounted to the panel on four (4)
plastic mounting studs, shown in Figure 55.
Figure 55. View of Control Board in E-Box
Backward/Forward Compatibility with Older Software Versions
With version 3.0 software release several of the boards used to control the
equipment will not be backward compatible with boards containing version 2.x of
the software. Please refer to the table below for compatibility.
Table 59.
Step
Action
1
Disconnect power from the unit.
2
Connect a static strap to your wrist and any convenient chassis ground on the
unit.
3
Unplug the eight (8) connectors from the control board.
4
Squeeze each of the mounting studs at the corners of the board while care-
fully lifting the board.
5
Replace the board with a new board.
6
Reverse the procedure to install the new board.
Mounting
Studs