Viper Service Manual
Publication Number: 621260373SER
- 64 -
© 2008-2012, IMI Cornelius Inc.
B
ARREL
M
OTOR
R
EPLACEMENT
The barrel motor does not require any special alignment when being replaced. It
mounts on four (4) bolts. These bolts are screwed into threaded bosses in the
foam pack barrel assembly, as shown in Figure 43. To replace a barrel motor,
perform the procedure in Table 46..
Figure 43. Side View of Motor Showing Two of the Four Mounting Bolts
M
OTOR
R
UN
C
APACITOR
R
EPLACEMENT
The motor run capacitors, shown in Figure 44, are mounted at the rear of the
unit between the barrel motors. To replace a run capacitor, perform the proce-
dure in Table 47..
Table 46.
Step
Action
1
Perform the procedure in Steps 1 through 8 of Table 43..
2
Disconnect the motor from the circuit by unplugging the connector.
3
Remove the motor by removing the four (4) bolts holding the motor to the bar-
rel assembly.
4
Install the replacement motor and connect the connector.
5
Replace the motor seal, scraper blade assembly onto the motor shaft in the
barrel, as described in Table 43..
6
Reconnect power to the unit.
7
Refill the barrel with product. See “Filling a Barrel” on page 37.
8
When barrel fill is complete, perform a motor calibration. See “Calibrating a
Motor” on page 44.
Barrel
Motor
Mounting
Bolts
Foam
Pack
Содержание VIPER 2 FLAVOR