Viper Service Manual
Publication Number: 621260373SER
- 40 -
© 2008-2012, IMI Cornelius Inc.
BRIX Setup Menu
BRIX is important to the quality of the final product. The BRIX menu facilitates the
extraction of a sample of product from the unit for BRIX measurement. There is an
automatic three second dispense of product that produces a constant volume so
that a BRIX comparison can be made between samples. To perform a BRIX test,
perform the procedure in Table 26.
MOTOR SEAL #1
HHHHH:MM
Shows how long it has been since the motor
seal was inserted on a specific barrel
DEFROST #1
HHHHH:MM
Shows how long the barrel has been in
defrost mode
FILL CYCLES #1
########
Shows the number of times the barrel has
filled with product
SYRUP RUN #1
HH:MM:SS
Shows how long the syrup solenoid has
been open
SYRUP OUT #1
HHHHH:MM
Shows how long the syrup has been out
ERROR #1
HHHHH:MM
Shows how long the barrel has had an error
Table 25
Display
Value
Description
Table 26
Step
Action
Procedure
1
Set status of barrels
Make sure the status of all barrels is OFF on
the control display.
2
Remove drip tray/
access panel
Remove the drip tray, loosen the two screws
holding the access panel and remove it. (Figure
30)
3
Set product supply
valve
Turn product supply valve to the 180 degree
(BRIX) position for the barrel you are testing.
(See Figure 31)
4
Access BRIX menu
Press MENU. Then press the SETUP button.
5
Set barrel for BRIX
From the Setup screen (Figure 19), open the
BRIX Setup screen, shown in Figure 29
6
Use the Up and Down arrows to highlight BRIX
SETUP. Press the GO button at the bottom of
the display.
7
Select barrel
Use the Up and Down arrows to highlight the
desired barrel for BRIXing.
8
Perform BRIX proce-
dure
Locate the appropriate barrel sample tube and
hold a cup under it.
9
Open the valve at the end of the sample tube.
Press the BRIX button, and wait 3-5 seconds.
The product pump pumps product for approxi-
mately 3 seconds. After the sample is dis-
pensed Press BRIX twice more to dispense
product two more times. Discard all three of
these samples.
10
Press the BRIX button a fourth time. Collect this
sample in a cup and close the valve at end of
the sample tube.