![Cornelius VIPER 2 FLAVOR Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/cornelius/viper-2-flavor/viper-2-flavor_service-manual_2667941058.webp)
Viper Service Manual
© 2008-201, IMI Cornelius Inc.
- 53 -
Publication Number: 621260373SER
Servicing Motorman Dispensing Valves
NOTE: Dispensing valves with caged o-rings should be serviced (lubri-
cated) every six months and o-rings should be replaced once a year.
Refer to Figure 39 and perform the procedure in Table 37. to lubricate or change
the caged o-rings in each dispensing valve on the unit.
Figure 38. Self-Closing Dispensing Valve
Table 36.
Step
Action
1.
Open the merchandiser and select OFF for the barrel to be cleaned.
2.
Remove the quick disconnect from the BIB container.
3.
Fill a suitable pail or bucket with soap solution.
4.
Submerge the disconnect in the soap solution and then clean it using a nylon
bristle brush. (Do not use a wire brush). Rinse with clean water and dry.
Table 37.
Step
Action
1.
Defrost freeze cylinders, shut unit down, disconnect electrical power from Unit.
2.
Perform the procedure in Table 38. to empty the barrels.