There are several procedures that should be completed on a semi-annual basis.
There procedures help to insure proper operation of the system on a long term
basis. Refer to Table 33. for a listing of the semi-annual maintenance items.
Inspecting and Replacing Scraper Blades
Scraper blades should be inspected for wear during the semi-annual mainte-
nance check. To inspect the blades, perform the procedure in Table 35.
Cleaning the Syrup Connections
Syrup connections should be cleaned at least every six months, or when syrup
types are changed. Perform the procedure in Table 36. to clean the BIB connec-
tors.
Table 35.
Step
Action
1.
See “Purging a Barrel” on page 36.
2.
When purging is complete, remove power from the unit.
3.
Remove the four (4) 3/4 in. nuts from the faceplate and slowly remove the
faceplate from the unit.
4.
Slowly pull the blade assembly out of the barrel.
5.
Rinse and inspect the blade assembly for signs of wear.
6.
If there is significant wear on the blades, Reverse or replace them, depending
on the wear pattern.
7.
Replace the blade assembly and bushings (PN 2392) onto the motor shaft in
the barrel.
8.
Re-install the faceplate and replace the four (4) mounting nuts. Hand tighten
the nuts untill the faceplate makes contact with the gasket, then use a wrech
to tighten the nuts an additional 1/4 turn. Be careful not to over tighten the nuts
or cracking of the faceplate may result.
9.
Refill the barrel with product. See “Filling a Barrel” on page 37.
10.
When barrel fill is complete, perform a motor calibration. See “Calibrating a
Motor” on page 44.