Viper Service Manual
© 2008-2012, IMI Cornelius Inc.
- 67 -
Publication Number: 621260373SER
S
YRUP
AND
W
ATER
S
HUTOFF
S
OLENOID
R
EPLACEMENT
The syrup and water shutoff valves and solenoids are mounted on a single
bracket, as shown in Figure 47. Perform the procedure in Table 50. to replace
the valves.
Figure 47. View of Shutoff Solenoids w/ Access Panel Removed (2 Barrel Unit)
Table 49.
Step
Action
1
Disconnect power from the unit.
2
Disconnect the CO
2
supply from the unit.
3
Remove the rear cover and side panels.
4
Carefully remove the tubing from the right-angle fitting at the rear of the valve.
Be sure not to damage the CO
2
metering orfice located above the fitting (Fig-
ure 46).
5
Remove the tubing from the front of the valve.
6
Remove the two (2) locknuts mounting the valve and solenoid to the base.
7
Remove the two (2) mounting screws from the bottom of the mounting bracket.
8
Replace the valve and solenoid.
9
Reverse the procedure to reinstall the valve and solenoid into the unit.
10
Test the unit for CO
2
leaks.
11
Replace the rear and side panels.
12
Reconnect power to the unit.
Syrup
Shutoff
Valves
&
Water
Shutoff
Valves
&
Solenoids
Solenoids