Viper Service Manual
© 2008-201, IMI Cornelius Inc.
- 56 -
Publication Number: 621260373SER
Sanitizing the Barrel
Sanitize the syrup system and barrel by performing the procedure shown in
Table 40..
4.
Hold a waste container under the brix tube to collect syrup from the syrup line
and open the manual syrup flow valve (see Figure 32) to start filling the syrup
line with plain water. Continue to hold the manual syrup flow valve open until
clean water starts coming out of the BRIX tube.
5.
Release the manual syrup flow valve and turn the Product/BRIX valve to the
Product position.
6.
Open the manual water flow valve (see Figure 32) to start filling the barrel with
water. At the same time, open the faceplate relief valve until water comes out.
7.
When the barrel is full, press the SPIN button on the Barrel Status menu, while
highlighting the appropriate barrel. This starts the scraper blade. Allow blade
to operate for fifteen seconds.
8.
Turn barrel OFF by pressing the OFF button.
9.
Place a waste container under the barrel dispensing valve. Open the dispens-
ing valve and dispense all wash water from the barrel. When the pressure in
the barrel drops, from the Barrel Maintenance menu, press the PURGE button
to re-pressurize the barrel with CO
2
. As the wash water level lowers in the bar-
rel, partially close the valve to avoid spurting.
10.
Perform rear barrel seal replacement. See “Barrel Motor Seal Replacement”
on page 61.
11.
Perform inspection and replacement of scraper blades. See “Inspecting and
Replacing Scraper Blades” on page 52.
12.
Perform a leak test on the barrel. See “Motor Seal Leak Test” on page 63.
Table 39.
Step
Action
Table 40.
Step
Action
1.
Use a clean 5-gallon pall filled with a sanitizing solution and water at a temper-
ature of 90º F to 110º F (32º C to 43º C). The sanitizing solution must have
200-ppm available chlorine.
2.
Connect a sanitizing fitting (p/n cc 28688) to the BIB connector. Put the con-
nector in the bucket of sanitizing solution.
3.
Make sure the
Product/BRI
X valve in the
BRIX
position.
4.
Hold waste container under the BRIX tube to collect flush water from the syrup
line and open the manual syrup flow valve to start filling the syrup line with
sanitizing solution. Continue to hold the syrup flow valve open until sanitizing
solution starts coming out of the BRIX tube.
5.
Turn the
Product/BRI
X valve in the
Product
position.
6.
Manually override (open) the syrup flow valve to fill the barrel with sanitizing
solution.