![Cooper Crouse-Hinds D2 W MDME 2400 1 Скачать руководство пользователя страница 59](http://html1.mh-extra.com/html/cooper-crouse-hinds/d2-w-mdme-2400-1/d2-w-mdme-2400-1_manual_2662005059.webp)
Chapter Three
Operation
Page 59 November
2008
Client 1 Configuration.
Perform the same configuration steps as the Access Point configuration with the following
differences:
•
Set the Ethernet and Wireless IP addresses of D2 W MDME 2400 to 192.168.0.201.
•
Set the Operating Mode to Client.
Ensure the same System Generator String is used and the same Radio Encryption method is
selected.
Client 2 Configuration.
•
Same as above, however, set the Ethernet and Wireless IP addresses as 192.168.0.202.
Alternate procedure
– Adjust D2 W MDME 2400 network settings using serial port
(assuming configuration PC is on existing network).
a)
Open terminal program with settings with data rate 19200bps, 8 data bits, 1 stop bit and
no parity.
b)
Set dip switch to SETUP.
c)
Connect straight-through serial cable to D2 W MDME 2400 and power up unit.
d)
When prompted, strike the Enter key to abort automatic boot.
e)
Set IP address of D2 W MDME 2400 to 192.168.0.200 with command bip
192.168.0.200.
f)
Set netmask of D2 W MDME 2400 to 192.168.0.200 with command bnm 255.255.255.0.
g)
Set gateway address of D2 W MDME 2400 to 192.168.0.1 with command bgw
192.168.0.1.
h)
Set dip switch to RUN.
i)
Reset D2 W MDME 2400 with reset command.
j)
Open configuration web page with Internet Explorer at address http://192.168.0.200/.
When prompted for password, enter default username “user” and password “user.”
Enter “Network,” and select Operating Mode as Access Point.
Select Device Mode as Bridge.
Change the IP address to 192.168.0.200.
Enter a System Address (SSID) string.
Select the Radio Encryption required, and enter the system keys. Make a record of these
Encryption keys and use these on all modules in the system.
Set dipswitch to RUN
Save the changes and unit will restart with new settings.