6. Gas exhaust conduction
46
EN
Gas exhaust conduction position, see
point (K, L) in connection plan.
•
Gas units produce exhaust gas that
must be adequately vented through a
conducting system.
•
In order to avoid an inadmissible
concentration of health threatening
combustible product in the installation
area, the unit must be installed with
sufficient ventilation conditions (Room
air ventilation system with safety
switch)
•
Combi steamers can be connected as
follows:
–
Under an ventilation hood
→
,
:
Unit type all sizes of appliance
–
Direct to the chimney
→
: or
under a ventilation ceiling
→
:
Appliance with air baffle (optional)
•
When installing the unit on a
ventilation ceiling or a ventilation
hood, you must ensure that the safety
arrangements are maintained, that
the gas shuts off automatically when
the flue is not functioning.
•
When connecting unit type B13 direct
on a chimney, the gas exhaust
conduction ways must be cleaned
regularly. Observe the country codes
and regulations.
•
Gas exhaust pipes with sealed tight
connections.
•
The unit, that is the gas exhaust
conduction must be ensured against
movement or loosening of alignment.
•
The gas exhaust conduction must be
inspected by an authorized ventilation
specialist and installed in accordance
with district ventilation codes. It is
recommended that a written report of
the inspection be kept.
•
Exhaust temperature can be 300 -
400°C.
•
No flammable surfaces or materials in
the area. Fire protection regulations
must be adhered to!
•
Attention, inform the user of the
following:
–
The exhaust vents, their covering
(rear left) and the exhaust gas
itself can be of a very high
temperature. Exhaust gas and hot
steel parts can lead to
burns
.
–
The
hand shower must only be
used for cleaning the inside
of
the oven and not for the outer
casing! Do not spray the air inlets
and outlets and gas exhaust
openings.
–
Do not place any flammable
materials or objects on the unit.
Danger of burning
.
The exhaust gas values are to be checked
when starting up.
CO < 500 ppm
Erdgas
8.6% ... 9.6% CO
2
Liquid Propane gas
10.0 … 11.0 % CO
2
Liquid Butan gas
11.7 … 12.7 % CO
2
In the event of deviations from these
values, the appliance is to be adjusted..
Picture 18
Picture 19
Содержание OEB 10.10
Страница 7: ...Notizen 3 DE...
Страница 37: ...Notes 33 EN...
Страница 67: ...Notes 63 FR...
Страница 113: ...Bilder pictures Images Afbeeldingen Figuras 19 6 20 7 21 11 1 22 11 2 23 11 2...
Страница 114: ...Bilder pictures Images Afbeeldingen Figuras 24 11 3 25 11 3...
Страница 115: ...Bilder pictures Images Afbeeldingen Figuras 26 11 4 27 11 4 28 11 4 29 11 6 30 12 31 12...