2. Positioning
38
EN
Use wooden spacers for standing units.
)
•
Lift table units with carrying strap (Part
No.3007089) from the pallet. Note the
weight of the units.
see Chapter 2.1
(chart with unit weights).
2.4
Installation / Distancing the
combi steamer
•
Note the
minimum
distance to
neighboring units/ walls (non
flammable).
*
The distance to the right of 50 mm or
75 mm is enough for the unit door to
open 90° or 180°.
In order to slide the disappearing door
along the side of the unit towards the
back, a
distance of 170 mm
is
necessary.
•
Position the combi steamer so that it
can’t tip or slide.
•
Air vents on the unit floor
→
as well
as air vents or gas exhaust vents
→
on the top of the unit must not be
blocked, adjusted or covered.
•
Table units
–
Position the unit at a minimum of
620 mm distance from the floor on
the stand or table, so that the hand
shower doesn’t fall on the kitchen
floor.
–
After positioning the unit, apply the
label at a height of 1.60 m
→
"
Danger of burns
" permanently.
–
Align the stand on the installation
site using the height adjustable legs
so that the unit is level.
Position the combi steamer level on
the stand with the height adjustable
feet.
–
When placing the table units on the
stand, the unit feet must be fixed
against the stop bolts on the stand.
–
When installing the combi steamer
on a stand with wheels, make sure
they are locked (also when
changing the site) before the
energy, water and drain connections
are made. This way, damage to
energy, water and drain connections
due to movement of the unit is
avoided. Make sure that the
energy, water and drain are
correctly disconnected before
moving the unit.
•
Standing units
–
Adjust the height with the height
adjustable feet on the combi
steamer using a water level, so that
the oven is level.
–
The kitchen floor in the area where
the trolley stands must be level and
even.
–
The trolley must stand level in the
unit. If required, use a roll-in ramp
on site max. 4° angle (by customer).
–
If there is a drain grid in front of the
unit, use something that will enable
the loading trolley to roll over it (by
customer).
Picture 6/7
left:
100 mm
rear:
50 mm
right:
- Table units
50 mm
*
- Stand ing units
75 mm
*
Other heat sources
:
min. 500 mm
Other heat sources
(hot grease)
working radius of
hand shower
air ventilation upwards:
- for Electric units
min. 500 mm
- for Gas units
Chapter 6.
Gas exhaust
- for Stacking kit
Chapter 11.3
Picture 8
Picture 9
Picture 16
Picture 5
Picture 11
Picture 10
Picture 9
Picture
10/11
Picture 12
Picture 10
Picture 10
Picture 3/4
Содержание OEB 10.10
Страница 7: ...Notizen 3 DE...
Страница 37: ...Notes 33 EN...
Страница 67: ...Notes 63 FR...
Страница 113: ...Bilder pictures Images Afbeeldingen Figuras 19 6 20 7 21 11 1 22 11 2 23 11 2...
Страница 114: ...Bilder pictures Images Afbeeldingen Figuras 24 11 3 25 11 3...
Страница 115: ...Bilder pictures Images Afbeeldingen Figuras 26 11 4 27 11 4 28 11 4 29 11 6 30 12 31 12...