88
Epsilon EP-P Drive Reference Manual
www.controltechniques.com
Revision: A4
Figure 102:
Jog View
Jog Number
This box allows you to select between Jog0 and Jog1 setup views.
Jog Name
This is a descriptive character string which can be assigned to the specific jog. Giving a name to a jog can make the motion setup easier to
follow.
Time Base
This list box allows the user to select between a jog that is based on time (Realtime) as defined by user units, normally in seconds, or a time
based on Master position via an external encoder (Synchronized) set in the Master Units View.
Jog Velocity
This parameter specifies the target jog velocity for the individual Jog. The motor will run at this velocity when jogging with an assignment or
through a program. This value is a signed number. The direction of the jog is determined by the sign of the jog velocity as well as using the
Jog.PlusInitiate or the Jog.MinusInitiate.
Jog Acceleration
This is the acceleration ramp used when initiating this individual Jog. If S-Curve ramps are used, then this is the average acceleration rate for
the entire ramp. The units for the acceleration are setup in the Setup - User Units view in PowerTools Pro.
Jog Deceleration
This is the deceleration ramp used when stopping this individual Jog. If S-Curve ramps are used, then this is the average deceleration rate for
the entire ramp. The units for the deceleration are setup in the Setup - User Units view in PowerTools Pro.
3.34.1 Jog Sources and Destinations
Sources
The following source functions can be found in the Assignments view under the Jog setup group:
Jog.AnyCommandComplete
The Jog.AnyCommandComplete source will activate when either Jog0 or Jog1 completes its deceleration ramp, and reaches zero
commanded velocity. It will deactivate when any Jog is initiated again. If the Stop destination is used during a Jog, then the
Jog.AnyCommandComplete will not activate.
Jog.#.Accelerating
This source is active while a jog is accelerating to its target velocity. Once the Jog reaches the target velocity, the Jog.#.Accelerating source
will deactivate.
Jog.#.AtVel
This source activates when the individual jog reaches its target velocity. It deactivates when a jog deceleration ramp begins.
Jog.#.CommandInProgress
The Jog.#.CommandInProgress source is active throughout an entire jog profile. The source activates at the beginning of a jog acceleration
ramp, and deactivates at the end of a jog deceleration ramp.
Jog.#.CommandComplete
The Jog.#.CommandComplete source will activate when the specific jog completes its deceleration ramp. It will remain active until the specific
jog is initiated again. If the Stop destination is used during a Jog, then the Jog.#.CommandComplete will not activate.
Содержание Epsilon EP-P
Страница 2: ......
Страница 14: ...xii Epsilon EP P Drive Reference Manual www controltechniques com Revision A4 Glossary 225 Index 231...
Страница 124: ...110 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Страница 200: ...186 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Страница 218: ...204 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Страница 238: ...224 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Страница 244: ...230 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Страница 247: ......