Epsilon EP-P Drive Reference Manual
183
Revision A4
www.controltechniques.com
Scaling
VelocityUnits.ScalingEnable
This parameter enables separate velocity and distance user units, name and scaling. If disabled, the velocity units, name and
scaling will be defined by the Distance Group.
Time Scale
VelocityUnits.TimeScale
Velocity time scale can be set to user units per second or user units per minute, used for all real-time velocities throughout the
PowerTools Pro software.
Acceleration
VirtualMaster.Accel
This parameter is the acceleration rate, in user units, that the virtual master will use to accelerate. This parameter is used
when in either jog or indexing mode.
Scaling
VirtualMaster.CharacteristicDistance
The denominator (bottom value of the scaling fraction) is the VirtualMaster.CharacteristicDistance and is used with
VirtualMaster.CharacteristicLength to create the virtual master conversion ratio. Converting the user units distance into virtual
counts.
ScalingVirtualMaster.CharacteristicLength
The numerator (top value of the scaling fraction) is the VirtualMaster.CharacteristicLength and is used with
VirtualMaster.CharacteristicDistance to create the virtual master conversion ratio scaling. Converting the user units distance
into virtual counts.
Command Complete
VirtualMaster.CommandComplete
This parameter indicating when a Virtual Master index or jog is complete.
Command In Progress
VirtualMaster.CommandInProgress
This parameter is an output event indicating a Virtual Master index or jog is currently being executed.
Counts
VirtualMaster.Counts
This read only parameter is the number of virtual counts transmitted. It is zeroed on power up only.
Deceleration
VirtualMaster.Decel
This parameter is the deceleration rate, in user units, that the virtual master will use to decelerate. This parameter is used
when in either jog or indexing mode.
Distance
VirtualMaster.Dist
This parameter is the incremental distance virtual master will move, in user units, if the virtual master is initiated as an index.
FeedRate Deactivate
VirtualMaster.FeedRateDeactivate
When this parameter is activated, from an assignment or a program, virtual master feedrate override is deactivated meaning
that the virtual master counts will be 100%.
Scaling =
Virtual MasterCharacteristicLength
VirtualMaster.CharacteristicDistance
Содержание Epsilon EP-P
Страница 2: ......
Страница 14: ...xii Epsilon EP P Drive Reference Manual www controltechniques com Revision A4 Glossary 225 Index 231...
Страница 124: ...110 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Страница 200: ...186 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Страница 218: ...204 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Страница 238: ...224 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Страница 244: ...230 Epsilon EP P Drive Reference Manual www controltechniques com Revision A4...
Страница 247: ......