Command Reference Manual
1118
Conexant
3-25
Reporting Current or Selected Values
Command:
+MS?
Response:
+MS: <carrier>,<automode>,<min_tx_rate>,<max_tx_rate>,<min_rx_rate>,<max_rx_rate>
Note: The current active settings are reported under control of the +MR parameter.
Example:
+MS: K56, 1,75,33600,75,56000
For default values. This example allows maximum system flexibility
to determine optimal receive and transmit rates during operation.
Reporting Supported Range of Parameter Values
Command:
+MS=?
Response:
+MS: (< carrier> range),(<automode> range),(<min_tx_rate> range),(<max_tx_rate> range),
(<min_rx_rate> range), (<max_rx_rate> range)
Example:
+MS: (B103,B212,V21,V22,V22B,V23C,V32,V32B,V34,K56,V90),(0,1),(75-33600),(75-33600),
(75-56000),(75-56000)
Result Code
OK
Valid subparameter string
ERROR
Otherwise.
3.2.4.2 +MR - Modulation Reporting Control
This extended-format numeric parameter controls whether or not the extended-MCR: <carrier> and +MRR: <rate>
intermediate result codes are transmitted from the modem to the DTE (see Section 3.5 and Table 3-14). If enabled, +MCR:
<carrier> and +MRR: <rate> intermediate result codes represent the current (negotiated or renegotiated) modulation <carrier>
and <rate> that are transmitted at the point during connect negotiation (handshaking) at which the modem has determined
which modulation and rate will be used, i.e., before any Error Control or Data Compression reports are transmitted, and
before any final result code (e.g., CONNECT) is transmitted.
S95 bit 2 is reset to 0 for +MR=0 and is set to a 1 for +MR=1 or +MR=2. The more recent setting of +MR or S95 bit 2, and the
W command setting, determines modulation result code reporting (see S95 Parameter and W Command).
Syntax
+MR=[<value>]
Defined Values
<value>
A decimal number corresponding to the selected option:
0
Disables reporting of modulation connection (+MCR: and +MRR: are not transmitted).
1
Enables reporting of modulation connection (+MCR: and +MRR: are transmitted).
(Default.)
2
Enables reporting of modulation connection (+MCR: and Receive Rate Only: are
transmitted).
Reporting Current or Selected Values
Command:
+MR?
Response:
+MR: <current value>
Example:
+MR: 1
For default setting
Reporting Supported Range of Parameter Values
Command:
+MR=?
Response:
+MR: (<value>range)
Example:
+MR: (0,1,2)
Содержание H08-15350
Страница 1: ...Doc No 1118 Rev 2 February 5 1999 RPPDQGV IRU RVW 3URFHVVHG DQG RVW RQWUROOHG 0RGHPV 5HIHUHQFH 0DQXDO ...
Страница 8: ...Command Reference Manual viii Conexant 1118 This page is intentionally blank ...
Страница 10: ...Command Reference Manual Conexant 1118 1 2 This page is intentionally blank ...
Страница 80: ...Command Reference Manual Conexant 1118 3 62 This page is intentionally blank ...
Страница 116: ...Command Reference Manual Conexant 1118 5 22 This page is intentionally blank ...
Страница 119: ...INSIDE BACK COVER NOTES ...