48
TROUBLE SHOOTING GUIDE
17.
Problem
Solution
Cable becomes jammed in the conduit
system
1. Inform the people at the other end
of the conduit that a problem has been
experienced and the operator is going to
shut down the system.
2. Shut off the pneumatic air supply with the
Ball Valve turning it to the 9 o’clock position,
allowing the air pressure to be depressurized
from the conduit and the airblock.
3. Using the counter or the measurement
on the cable, determine where the blockage
might be located.
4. Notify supervisor about problem and
determine a solution accordingly.
Machine speed slows or motors start to
labor.
Assist the reel by pushing it or by pulling the
cable off the reel.
It is difficult to keep the cable moving
near the end of the conduit run.
Assist the blower by manually pushing the
cable into the conduit.
Do not bend or crimp the cable.
The cable run is hard to restart after
having stopped.
Put air to the system with the belt drive
down. The tractor feed can be restarted after
the air pressure has increased and stabilized.
GPS coordinates not showing.
Make sure the tablet location is on and in
Tablet only mode, unless there is a cellular
plan.
Tractor feed doesn’t start.
1.Pneumatic control is at the lowest speed -
increase flow speed slowly.
2. E-stop
is still in the active mode - rotate
clockwise to allow the button to reset.
Содержание Gulfstream 350e
Страница 1: ...Gulfstream 350e USER S GUIDE SAFETY MANUAL...
Страница 2: ......
Страница 3: ...3...
Страница 17: ...17 Figure 22 Insert USB Figure 23 Copy to USB...
Страница 19: ...19 Figure 26 WIFI On Figure 27 Select GS350 e Enter password Condux145 passwords are case sensitive f Connect...
Страница 50: ...50 Notes...
Страница 51: ...51 Notes...