38
6. Close the Air Block Cover. Tighten nuts securely, but do not over tighten (Figure 68). Use
cross tightening procedure with the rachet to secure completely.
7. Spread lubricant through Conduit.
a. Re-connect the air hose to the fiber blower and attach all safety clips (Figure 69).
b. Turn the Ball Valve handle to the 9 o’clock position and turn on the air from the
compressor (Figure 62).
c. Slowly open Ball Valve by turning to the 9 o’clock position.
d. Make sure Needle Valve is open (Figure 70).
e. Blow Foam Carrier through conduit to spread lubricant and check for blockage. Follow
all safety precautions.
f. After the Foam Carrier exits, close Ball Valve.
NOTE: Foam Carrier must exit in a reasonable time, allow for approximately 10 seconds per
1,000 feet (300 m) for traditional duct. If longer than 10 seconds duct may be contaminated
or blocked. Micro duct will take longer depending on the length of the run.
Figure 68. Close Air Block
Figure 69. Connect Air
Figure 70. Air Block Open