36
PREPARE CONDUIT PROOF & PREPARE CONDUIT FOR INSTALL
1. Remove Pulling Grip and then remove Conduit Pulling Eye or End Stop from exiting
end of Conduit. After removing pulling eye or end stop, re-install pulling grip in order to
catch Foam Carrier during conduit lubrication (Figure 64).
2. Open the Air Block Cover (Figure 65).
3. Pour recommended (silicon-based) lubricant into Conduit opening before Foam
Carrier: 1 quart/6000 feet (1 liter/2 km) (Figure 66). (See Page 37 for lubricant chart)
4. Foam Carrier comes with Traditional Duct Packs. Micro Ducts you will need a pressure
and proofing kit. Insert Foam Carrier (selected according to conduit size) into Conduit
(Figure 67).
5. Insert Seal Disk in venturi slot (Figure 56) if not already in place.
Figure 64. Install Pulling Grip
Figure 65. Air Block Cover
Figure 66. Add Lube
Figure 67. Install Foam Carrier