34
9. Plug receiving end of Conduit with a suitable sized Conduit Pulling Eye or micro duct
end stop (Figure 58).
10. Choose the correct Pulling Grip & install on receiving end of Conduit over pulling eye
or end cap (Figure 59).
11. Connect the Air Compressor (Figure 60).
a. Ensure Air Valve is off before connecting air hose (Figure 61).
b. Attach the hose from the air compressor to the air machine coupling. The blower
air valve assembly is equipped with a claw type connector. Use safety clips on all
pneumatic hose connections.
c. Observe all safety procedures (See page 9).
d. Route all hoses properly to prevent tripping over them.
e. Forced air potentially creates flying debris. Always wear personal
protective equipment. Severe personal injury could result.
f. Ensure no personnel are in the destination access vault during the
blowing operation. Severe personal injury could result.
Figure 58. Install End Stop
Figure 59. Install Pulling Grip
Figure 60. Connect Air Compressor
Figure 61. Ball Valve in the
Off Position