Operating Instructions
LASSTEC
Weighing System 0521
BAL0521-0001-EN
www.conductix.com
translated document
page 84 of 123
⑦
Datalogging:
A recorded pictogram: appear when the datalogging of the current load cycle is in progress and then: when the
datalogging is done.
⑧
O.H.F TARE:
Saved Tare (unladen weight), generated with Button “3_3”.
⑨
Open Container Weight:
Weight without the Tare (the stabilized weight is not displayed).
Alarm indication:
Alarms:
Snag load alarm individual for each Twistlock (blinking “SNAG LOAD” indication and red background of the concerned Twistlock
weight).
Over-eccentricities alarms (X-; X+; Y-; Y+; blinking “OVER ECCENTRICITY” indication according to the side of the alarm).
Limit load alarm (or 1
st
overload alarm; blinking “LIMIT LOAD” indication, yellow background of the current container weight and
the container become yellow).
Overload alarm (blinking “OVERLOAD” indication, red background of the current container weight and the container become
red).
A trailer lift alarm appears when the system detects a lifted trailer.
Dragging Alarm (blinking “DRAGGING” indication).
Not Carrying Twistlock (blinking “NOT CARRYING” indication, for each Twistlock).