5.3.8.3.5
Not carrying Detection
DANGER!
The Lasstec Not carrying detection is to be used only as an informative function and in no case as
a security-relevant function. Conductix-Wampfler is not to be held responsible for injuries or damage
caused by an un-triggered or disregarded alarm.
Container weight to start detection [Ton]
Threshold which defines the minimum container weight after which the
function is enabled
Timer after container weight detection [s]
Timer threshold after which the detection is enabled
Twistlock weight to not detect [Ton]
Twistlock weight threshold
Timer before Pstab to Twistlock detection [s]
These timers are defining a time range in which the function is enabled
Timer after Pstab to Twistlock detection [s]
Minimum alarm timer [s]
Minimum duration of the alarm