Operating Instructions
LASSTEC
Weighing System 0521
BAL0521-0001-EN
www.conductix.com
translated document
page 95 of 123
Alarm bit false
(red background)
Alarm bit true
(green background)
Description
Alarm on sensor 8
1)
Sensor 8 OK
Indicates if there is an alarm on the sensor 8 (broken sensor, bad
connection, broken cable...).
Spreader telescopic position
not defined
Spreader telescopic
position defined
Indicates if the interrogator does not receive the telescopic position of
the spreader (hard wiring).
Loss power supply of the time
data
RTC OK
Indicates if the date and time of the interrogator was lost and need to be
set.
Twin down with single-lift
interrogator
2)
-
Indicates if a signal is fed into the twin-down input of the interrogator
although it is a single-lift interrogator. In this case the measurement is
blocked.
Twistlock nor lock nor unlock Twistlock position defined Indicates if the interrogator does not receive the Locked or Unlocked
signal from the spreader (hard wiring).
Communication error with
Interrogator
Communication with
Interrogator OK
Indicates if there is no communication with the interrogator.
Communication error with
gateway
Communication with
gateway OK
Indicates if there is no communication with the gateway. (if declared)
TCP/IP server not present on
the network
TCP/IP server present on
the network
Indicates if there is no communication with the TCP/IP server. (if
declared)
TCP/IP server port not open
TCP/IP server port open Indicates if TCP/IP server port is open. (if declared)
Upload datalogging not OK Upload datalogging OK Indicates if the data logging works
1)
= Only available with the twin-lift system.
2)
= Only available with the single-lift system.
Navigation:
Button
Action
1_2
Go on page Status
1_3
Go on page configuration of the screen
1_4
Go on page load alarms
3_4
Exit the current page and go on home page
DANGER!
If a fault occurs, the load has to put down. A new weighing operation may only carry out after
the error has been rectified.