Operating Instructions
LASSTEC
Weighing System 0521
BAL0521-0001-EN
www.conductix.com
translated document
page 93 of 123
Alarm bit false
(green background)
Alarm bit true
(red background)
Description
Overload Twistlock 6
Overload Twistlock 6
Indicates if there is an overload on the Twistlock 6.
Overload Twistlock 7
Overload Twistlock 7
Indicates if there is an overload on the Twistlock 7.
Overload Twistlock 8
Overload Twistlock 8
Indicates if there is an overload on the Twistlock 8.
NO Snag load container 2
Snag load container 2
Indicates if there is a snag load on one or more spreader
Twistlocks of container 2.
NO Overload container 2
Overload container 2
Indicates if there is an overload on the container 2.
NO Limit load container 2
Limit load container 2
Indicates if the limit load (or 1
st
overload) is reached on the
container 2.
NO Over eccentricity X
container 2
Over eccentricity X container 2 Indicates if there is a longitudinal over eccentricity on the
container 2.
NO Over eccentricity Y
container 2
Over eccentricity Y container 2 Indicates if there is a transversal over eccentricity on the
container 2.
Navigation:
Button
Action
1_2
Go on page Status
1_3
Go on page configuration of the screen
1_5
Go on page system alarms
3_3
Exit the current page and go on alarms 1
3_4
Exit the current page and go on home page
DANGER!
If a fault occurs, the load has to put down. A new weighing operation may only carry out after
the error has been rectified!
The Lasstec Overload, eccentricity, snag load, trailer lift, dragging and not carrying detection are to
be used only as an informative function and in no case as a security-relevant function. Conductix-
Wampfler is not to be held responsible for injuries or damage caused by an un-triggered or
disregarded alarm.