5-14
Remote Commands and Error Codes
Error Codes
After a command is issued, the CM601 may return an error message indicating the
command request was not completed. Error message appears in the following
format:
ER <error code>
where:
ER indicates an error has occurred
<error code>
is a numerical parameter indicating the type of error
A description of each error code, including its probable cause and the action to be
taken to resolve the error, is provided in Table 5-4.
Table 5-4
Error Codes
ER #
Description
Problem
Action
ER 1
Command format error
Typographical errors, incorrect command mnemonic,
extra spaces between the command and the
parameter
Reenter the command using the correct
syntax.
ER 2
Invalid command
parameter
Parameter may be incorrect, out of range, missing, or
exceed 24 characters
Reenter the command using the correct
parameter.
ER 3
Command not
supported by current
hardware
Command does not match hardware configuration or
settings; for example, attempting a loopback test
when no modulator has been installed
Check hardware configuration and
settings and make modifications if
required. Reenter the command using
the correct syntax.
ER 4
Command temporarily
not supported
Command cannot be executed immediately. Example:
ER 4
will be returned if:
Receive offset query or Eb/No query is issued and
the demodulator carrier is not locked to a receive
carrier
Firmware configuration or mode does not
temporarily support the command, such as issuing
the BBC command before the BERT has been
enabled.
Wait for a short period of time and then
reenter the command.
ER 5
CM601 internal
communications error
Breakdown in microcontroller communications
between module cards
Reenter the command. Repeated
occurrences of this error message
suggest a bad connection between
cards or a faulty card in the system.
ER 6
Slot address required
More than one card can respond to the command
Reenter the command making sure that
the desired slot number is specified.
ER 7
Security error
Security is enabled and there is no current login, or an
incorrect password has been entered
Enter the correct password using the
LGN command.
Содержание CM601
Страница 4: ...iv Notice COMSTREAM A Spar Company...
Страница 12: ...xii Contents COMSTREAM A Spar Company...
Страница 86: ...6 14 Front Panel Operation COMSTREAM A Spar Company...
Страница 96: ...7 10 Configuration Examples COMSTREAM A Spar Company...
Страница 118: ...8 22 Fault Handling Troubleshooting and Maintenance COMSTREAM A Spar Company...
Страница 124: ...A 6 Technical Specifications COMSTREAM A Spar Company...
Страница 160: ...xii Safety Precautions 01 0799 401D 08 02...
Страница 164: ...4 Functional Description 01 0799 401D 08 02...
Страница 170: ...10 Card Removal Procedure 01 0799 401D 08 02...
Страница 204: ...44 Fault and Status Queries 01 0799 401D 08 02...
Страница 208: ...48 Loopback Tests 01 0799 401D 08 02...
Страница 216: ...56 Appendix A Technical Specifications and Pinouts 01 0799 401D 08 02...
Страница 220: ...60 01 0799 401D 08 02...
Страница 222: ...D 08 02 01 0799 401 Index 62...
Страница 223: ...01 0922 401 Rev A 4 03 1 Application Note Carrier Acquisition and Optimization CM601 CM701 Satellite Modem v1 80 1 84...