Preface
xix
An AC plug must be attached to the International power cord in accordance with
government standards and codes in effect at the CM601 installation site. If an
unterminated power cord is supplied with the unit, the appropriate certified termination
plug must be installed. The following is a list of the required certifying agencies for
various countries:
Route Power Cords Safely
Route power cords so that they are not walked on or pinched. Pay particular attention to
cords and connections at the plugs, receptacles (such as power strips), and the point where
they exit from the CM601 and attach to other equipment. Do not place any items on or
against power cords.
Protect Against Lightning and Power Surges
When the CM601 equipment is installed, have the professional installer ground the system
to protect against voltage surges and built-up static charges. It is recommended to install
system primary and secondary lightning/surge protective devices for CM601 units having
direct connection to external radio equipment. For information on grounding standards for
electrical and radio equipment, refer to the electrical code in the country of installation.
For example, in North America refer to the National Electrical Code (NEC) Article 250
for grounding, and Article 810 for radio equipment.
Protect the CM601 from lightning and power-line surges during a storm by unplugging it
from the wall outlet and disconnecting the coaxial cable.
Country
Agency
Australia
SAA
Austria
OVE
Belgium
CEBEC
Canada
CSA
Denmark
DEMKO
Finland
FEI
France
UTE
Germany
VDE
India
ISI
Ireland
IIRS
Italy
IMQ
Japan
MITI
Netherlands
KEMA
New Zealand
SECV
SECQ
SECWA
EANSW
ETSA
HECT
Norway
NEMKO
Rep. S. Africa
SABS
Spain
AEE
Sweden
SEMKO
Switzerland
SEV
United Kingdom (UK)
ASTA
BSI
Содержание CM601
Страница 4: ...iv Notice COMSTREAM A Spar Company...
Страница 12: ...xii Contents COMSTREAM A Spar Company...
Страница 86: ...6 14 Front Panel Operation COMSTREAM A Spar Company...
Страница 96: ...7 10 Configuration Examples COMSTREAM A Spar Company...
Страница 118: ...8 22 Fault Handling Troubleshooting and Maintenance COMSTREAM A Spar Company...
Страница 124: ...A 6 Technical Specifications COMSTREAM A Spar Company...
Страница 160: ...xii Safety Precautions 01 0799 401D 08 02...
Страница 164: ...4 Functional Description 01 0799 401D 08 02...
Страница 170: ...10 Card Removal Procedure 01 0799 401D 08 02...
Страница 204: ...44 Fault and Status Queries 01 0799 401D 08 02...
Страница 208: ...48 Loopback Tests 01 0799 401D 08 02...
Страница 216: ...56 Appendix A Technical Specifications and Pinouts 01 0799 401D 08 02...
Страница 220: ...60 01 0799 401D 08 02...
Страница 222: ...D 08 02 01 0799 401 Index 62...
Страница 223: ...01 0922 401 Rev A 4 03 1 Application Note Carrier Acquisition and Optimization CM601 CM701 Satellite Modem v1 80 1 84...