Installation
4-3
The uplink and downlink frequencies are the operational frequencies that
must be used, and they must be preauthorized by the space-segment
vendor or satellite operator.
The initial transmit power is the level authorized for satellite loopbacks
and end-to-end testing and may be different from the final power setting
level.
The minimum required E
b
/N
0
at the remote station reflects the minimum
value for acceptable system performance as calculated by the system link
budget. This value must be met during commissioning, or the installation
cannot be regarded as successful. The final E
b
/N
0
value should be
recorded and used as a baseline in determining system performance.
Other information includes the various modem operating parameters that
determine uplink power.
Configuration parameters – this section details the modem configuration for a
specific site. These parameters must be known and set to their proper values
before the bench-top test is performed.
Installation Data Sheet
Before beginning the physical setup and installation of the earth station
components, fill out the following questionnaire. It will save time and provide
ease of installation by identifying decisions about configuration that should be
made beforehand.
Installation Data Sheet
General Information
Date ___________________________Installer _________________________________________________________
Site location ________________________________________________________________________________
Customer
Name _________________________________________ P.O.C. and phone # _________________________________
Satellite
Name _________________________________________Longitude (degrees) ________________________________
Operating Parameters
Transmit frequency (TxIF) ________________ kHz
Tx power (TP) ________________ dBm
Receive frequency (RxIF) ________________ kHz
Min. required E
b
/N
0
(EB) ____________ dB
Final E
b
/N
0
(EB) ________________ dB
Configuration Parameters
Transmit
Receive
Data rate (bps)
PTD =_______
PRD =_______
Modulation type (BPSK/QPSK)
TM =_______ (0,1)
RM =_______ (0,1)
FEC type (off, S 1/2, S 3/4, V 1/2, V 3/4, V 7/8)
TC =______ (0,1,2,3,4,5)
RC =_______ (0,1,2,3,4,5)
Differential encoding (off, standard)
DM =_______ (0,1)
DD =_______ (0,1)
Scrambling (off, ComStream, IDR)
SM =_______ (0,1,2)
SD =_______ (0,1,2)
Acquisition offset (Hz)
AO =_______
Acquisition range (Hz)
AR =_______
Modulator bit timing (external, internal, loop)
MB =_______ (1,2,3)
Modulator latching clock (TT, ST)
ML =_______ (0,1)
Содержание CM601
Страница 4: ...iv Notice COMSTREAM A Spar Company...
Страница 12: ...xii Contents COMSTREAM A Spar Company...
Страница 86: ...6 14 Front Panel Operation COMSTREAM A Spar Company...
Страница 96: ...7 10 Configuration Examples COMSTREAM A Spar Company...
Страница 118: ...8 22 Fault Handling Troubleshooting and Maintenance COMSTREAM A Spar Company...
Страница 124: ...A 6 Technical Specifications COMSTREAM A Spar Company...
Страница 160: ...xii Safety Precautions 01 0799 401D 08 02...
Страница 164: ...4 Functional Description 01 0799 401D 08 02...
Страница 170: ...10 Card Removal Procedure 01 0799 401D 08 02...
Страница 204: ...44 Fault and Status Queries 01 0799 401D 08 02...
Страница 208: ...48 Loopback Tests 01 0799 401D 08 02...
Страница 216: ...56 Appendix A Technical Specifications and Pinouts 01 0799 401D 08 02...
Страница 220: ...60 01 0799 401D 08 02...
Страница 222: ...D 08 02 01 0799 401 Index 62...
Страница 223: ...01 0922 401 Rev A 4 03 1 Application Note Carrier Acquisition and Optimization CM601 CM701 Satellite Modem v1 80 1 84...