Fault Handling, Troubleshooting, and Maintenance
8-7
20
524288
Relay
Monitor
Pin 4
H
Fault reported by fault sense
signals on the rear panel
status relay connector
The CM601 monitors status relay pins and reports a
fault as defined by the FRX command.
21
1048576
—
—
Not used
—
22
2097152
—
—
Not used
—
23
4194304
Loss of
Doppler
Output Clock
O
Doppler buffer fault
The clock selected for clocking out of the buffer is
not present or out of range.
24
8388608
Relay
Monitor
Pin 5
H
Fault reported by fault sense
signals on the rear panel
status relay connector
The CM601 monitors status relay pins and reports a
fault as defined by the FRX command.
25
16777216
(Narrow option Tx
summary fault)
H or O Card-specific message.
Review the option card fault messages.
26
33554432
BERT Sync
Loss
(Narrow option Rx
summary fault)
H or O Internal BERT lost data
synchronization
The demodulator is not in sync and is not passing
valid data to the BERT.
Card-specific messages may also be associated
with this fault bit.
27
67108864
(Narrow option Tx
hardware fault)
H
Card-specific message.
Review the option card fault messages.
28
134217728
(Narrow option Rx
hardware fault)
H
Card-specific message.
Review the option card fault messages.
29
268435456
Tx FIFO Full
Fault
O
Data buffer on the modulator
has overflowed or
underflowed
Occurs briefly when changing modulator data rates
or timing (MB). In addition, if the modulator is
running external timing and the user-provided clock
(TT) does not match the clock expected by the
modulator (TD), this fault may occur. Excessive jitter
coming from DTE.
(Wide option Tx
summary fault)
H or O
—
Card-specific messages may also be associated
with this fault bit.
30
536870912
Low Eb/No
O
Demodulator E
b
/N
0
level has
dropped below the user-
specified threshold (EBT)
There has been a decrease in input power level,
probably due to a rain fade.
Output
Buffer Fault
H or O Data buffer on the
demodulator has overflowed
or underflowed
Occurs briefly during operation, for example, when
changing demodulator data rate.
If this fault is reported constantly, there is a
hardware problem in the demodulator.
(Wide option Rx
summary fault)
H or O
—
Card-specific messages may also be associated
with this fault bit.
31
1073741824
(Wide option Tx
hardware fault)
H
Card-specific message.
Review the option card fault messages.
32
2147483648
(Wide option Rx
hardware fault)
H
Card-specific message.
Review the option card fault messages.
Table 8-1
CM601 Faults (continued)
Bit
Weight*
Fault
Type
Description
Possible Cause
* Weight = (2
bit-1
)
Содержание CM601
Страница 4: ...iv Notice COMSTREAM A Spar Company...
Страница 12: ...xii Contents COMSTREAM A Spar Company...
Страница 86: ...6 14 Front Panel Operation COMSTREAM A Spar Company...
Страница 96: ...7 10 Configuration Examples COMSTREAM A Spar Company...
Страница 118: ...8 22 Fault Handling Troubleshooting and Maintenance COMSTREAM A Spar Company...
Страница 124: ...A 6 Technical Specifications COMSTREAM A Spar Company...
Страница 160: ...xii Safety Precautions 01 0799 401D 08 02...
Страница 164: ...4 Functional Description 01 0799 401D 08 02...
Страница 170: ...10 Card Removal Procedure 01 0799 401D 08 02...
Страница 204: ...44 Fault and Status Queries 01 0799 401D 08 02...
Страница 208: ...48 Loopback Tests 01 0799 401D 08 02...
Страница 216: ...56 Appendix A Technical Specifications and Pinouts 01 0799 401D 08 02...
Страница 220: ...60 01 0799 401D 08 02...
Страница 222: ...D 08 02 01 0799 401 Index 62...
Страница 223: ...01 0922 401 Rev A 4 03 1 Application Note Carrier Acquisition and Optimization CM601 CM701 Satellite Modem v1 80 1 84...