Configure the terminal as follows:
•
7 data bits
•
Odd parity
•
1 stop bit
•
1200 baud
4. Select an AC power cord and connect it to the CM601 IEC receptacle on the
rear panel, and plug the other end into an AC outlet. For additional
information on the power source and rules and regulations for attaching an
international power cord, refer to the Preface of this guide.
5. Power on the CM601. Press the rear panel rocker switch toward the On
position.
6. Monitor the message sequences on the front panel and remote terminal
displays. The power-up message sequences are presented in Table 4-2.
Table 4-2
Power-Up Sequence
Front Panel Power-Up Sequence
Remote Terminal Power-Up Sequence
LEDs illuminate for a short time while all
LED lamps are tested
CM601 information appears; for example:
ComStream CM601
ID message
Unit serial number
Pass or fail indication for the power-up,
self-test sequence
Power-Up Test Messages:
Power-Up Test in Progress
Power-Up Test Complete
message indicating the test passed or
failed
Information for each card installed in the
CM601 chassis appears:
Card description
Chassis slot location
Software version
Other hardware configuration information
ComStream CM601
identification
message appears indicating power-up is
complete
System prompt (>) appears indicating
power-up is complete
Troubleshooting Tip
If the terminal fails to display the power-up message sequence, check the following:
Cables
Remote terminal baud rate set at 1200
Terminal data/parity set at 7/odd
Once the parameters are correct, turn the power switch off and then back on. Monitor the power-
up message sequence on the remote terminal.
Содержание CM601
Страница 4: ...iv Notice COMSTREAM A Spar Company...
Страница 12: ...xii Contents COMSTREAM A Spar Company...
Страница 86: ...6 14 Front Panel Operation COMSTREAM A Spar Company...
Страница 96: ...7 10 Configuration Examples COMSTREAM A Spar Company...
Страница 118: ...8 22 Fault Handling Troubleshooting and Maintenance COMSTREAM A Spar Company...
Страница 124: ...A 6 Technical Specifications COMSTREAM A Spar Company...
Страница 160: ...xii Safety Precautions 01 0799 401D 08 02...
Страница 164: ...4 Functional Description 01 0799 401D 08 02...
Страница 170: ...10 Card Removal Procedure 01 0799 401D 08 02...
Страница 204: ...44 Fault and Status Queries 01 0799 401D 08 02...
Страница 208: ...48 Loopback Tests 01 0799 401D 08 02...
Страница 216: ...56 Appendix A Technical Specifications and Pinouts 01 0799 401D 08 02...
Страница 220: ...60 01 0799 401D 08 02...
Страница 222: ...D 08 02 01 0799 401 Index 62...
Страница 223: ...01 0922 401 Rev A 4 03 1 Application Note Carrier Acquisition and Optimization CM601 CM701 Satellite Modem v1 80 1 84...