6-6
Front Panel Operation
For example:
To navigate to 5:Modem from
Config Monitor Faults
, first press the
LCD button under
Config
. This displays
4:System 4:M&C More.
Select
More
. This displays
5:Modem More
.
Pressing the
Previous
button from this display takes you one level
higher (up) in the command tree to
Config Monitor Faults.
Selecting
More
from
5:Modem More
displays slot 1’s option cards,
such as
1:RS232 1:BERT More
, if these option cards are installed, or
System M&C More
if no option cards are installed in slot 1.
To navigate to System Loopback from
Config Monitor Faults,
select
Config
, then select
4:Systm
, then scroll through the options using
the down modify button until Loopback displays. To return to 4:Systm, press
Previous
.
A brief description of the function of each command tree level is provided in
Table 6-5.
Table 6-5
CM601 Front Panel Command Tree Levels
Level/Components
Description
Config
Access to commands that determine CM601 operating characteristics or direct
the CM601 to perform specific real-time functions
4:Systm
Macro, multi-card, and chassis configuration commands
4:M&C
Access to monitor and control functions
Remote – commands associated with the remote control interface port
S/W Ver – access to software version number of each installed card in the
CM601
Misc – miscellaneous M&C functions such as terminal emulation and
system self-test
5:Modem
Modulator, demodulator, and Doppler buffer commands
1:BERT
Access to BERT configuration and monitor commands:
BConfig – configuration commands used to access, modify, and issue
BERT commands
BMonitor – commands used to review the status results of the BERT
Monitor
Commands that report performance and nonfault information provided by
various monitoring points located within the CM601
Faults
Commands that provide information on the status of the CM601 or indicate
when an external piece of equipment is improperly configured or is faulty
FaultLog
Provides historical account of all faults that occurred since the last time the
faults were cleared; associated with yellow fault LED. A displayed fault is
preceded by the slot number of the card that is generating the fault message.
Current
Provides account of all faults present at any one point in time; associated with
red fault LED. A displayed fault is preceded by the slot number of the card that
is generating the fault message.
Clear
Erases the contents of the fault log
Содержание CM601
Страница 4: ...iv Notice COMSTREAM A Spar Company...
Страница 12: ...xii Contents COMSTREAM A Spar Company...
Страница 86: ...6 14 Front Panel Operation COMSTREAM A Spar Company...
Страница 96: ...7 10 Configuration Examples COMSTREAM A Spar Company...
Страница 118: ...8 22 Fault Handling Troubleshooting and Maintenance COMSTREAM A Spar Company...
Страница 124: ...A 6 Technical Specifications COMSTREAM A Spar Company...
Страница 160: ...xii Safety Precautions 01 0799 401D 08 02...
Страница 164: ...4 Functional Description 01 0799 401D 08 02...
Страница 170: ...10 Card Removal Procedure 01 0799 401D 08 02...
Страница 204: ...44 Fault and Status Queries 01 0799 401D 08 02...
Страница 208: ...48 Loopback Tests 01 0799 401D 08 02...
Страница 216: ...56 Appendix A Technical Specifications and Pinouts 01 0799 401D 08 02...
Страница 220: ...60 01 0799 401D 08 02...
Страница 222: ...D 08 02 01 0799 401 Index 62...
Страница 223: ...01 0922 401 Rev A 4 03 1 Application Note Carrier Acquisition and Optimization CM601 CM701 Satellite Modem v1 80 1 84...