5
Parameters
The CDD5.0 door drive can be configured by a parameters set, most of them are accessible also from the
door drive front panel. The following table reports all the parameters that can be changed by the door drive
front panel. The associated functions are described in detail in the next paragraphs.
The parameters
highlighted in the table represents the key parameter for the door operator configuration
.
N°
RANGE
DEFAULT
Name
Values Description
00
[0 ; 2]
0
Reversing events management
00 = internal
01 = external when moving
02 = external, parking
01
[0 ; 2]
0
MLC commands check
00 = level.
01 = level, also when parking.
02 = activation edge
02
[0 ; 2]
0
Door drive reaction on MLC commands
not present
00 = instant stop
01 = low speed + stop
02 = low speed cycle
03
[0 ; 1]
0
No MLC signal alarm
00 = disabled
01 = enabled
04
[0 ; 2]
0
RVC input option
00 = reversing on RVC edge
01 = reversing on RVC active level
02 = mechanical safety edge
05
[0 ; 1]
0
Car door locking device
00 = car door lock not present
01 = car door lock present
06
[0 ; 1]
0
Glazed door
00 = not present
01 = present
07
[0 ; 3]
3
AUXS output options
00 = disabled
01 = active during door opening
02 = active after space % reached
03 = Alarm signal
08
[0 ; 99]
50
Space percentage (related to PC07=2)
00 = door closed … 99 = door opened
09
[0 ; 99]
65
Closing force limit
00 = 100N … 99 = 150N (based on the motor)
10
[0 ; 99]
50(*)
Opening high speed
(*) con PC33 = 02
11
[0 ; 99]
34(*)
Opening low start speed
(*) con PC33 = 02
12
[0 ; 99]
80(*)
Opening profile fittings
(*) con PC33 = 02
13
[0 ; 99]
40(*)
Closing high speed
(*) con PC33 = 02
14
[0 ; 99]
16(*)
Closing final low speed
(*) con PC33 = 02
15
[0 ; 99]
99(*)
Closing profile fittings
(*) con PC33 = 02
19
[0 ; 1]
1
Fire-Fighting mode
00 = closing force detection disabled
01 = reduced sensitivity
20
[1 ; 5]
1
Battery opening cycle duration (related
to EOC command function)
Expressed in minutes
21
[0 ; 1]
0
Reversing source signal logic
00 = N.O.
01 = N.C.
22
[0 ; 1]
0
Closing rotation
00 = clockwise
01 = counter-clockwise
23
[0 ; 99]
70
% partial opening on AUXC active
00 = door closed … 99 = door opened
24
[0 ; 1]
0
Reopening with reduced profile
00 = disabled
01 = enabled
25
[0 ; 1]
0
Door closed parking mode
00 = skate closed (continuous torque on the
motor)
01 = skate opened (without additional torque
on the motor)