10
Compool Cp3830
Equipment Power
The diagram above shows how the filter pump is wired. Additional pumps should be wired the
same way.
•
To wire high voltage equipment
1.
At the Sub-panel, install circuit breaker. Run wires from circuit breaker to relay terminal
block LINE 1 and LINE 2.
2. Connect equipment to the relay terminal block LOAD 1 and LOAD 2.
Note If pump is greater than 3 H.P., install an external contactor. Use relay to switch coil of
external contactor.
Adding Relays
The Power Center comes standard with 4 relays. It is possible to add additional relays (model
RLY-LX). The LX-3830 Power Center has room for 7 relays, and the LX-3830L Power Center
has room for 8 relays.
LINE 1
LINE 2
LOAD 1
LOAD 2
R1
LINE 1
LINE 2
LOAD 1
LOAD 2
R2
LINE 1
LINE 2
LOAD 1
LOAD 2
R3
LINE 1
LINE 2
LOAD 1
LOAD 2
R4
LINE 1
LINE 2
LOAD 1
LOAD 2
R5
LINE 1
LINE 2
LOAD 1
LOAD 2
R6
LINE 1
LINE 2
LOAD 1
LOAD 2
R7
HIGH VOLTAGE RELAYS
FULL LOAD: 20AMP
LOCKED ROTOR: 60AMP
Lx3830
SUB-PANEL
Содержание Cp3830
Страница 1: ...Compool Cp3830 POOL SPA CONTROL SYSTEM Installation Operating Instructions 05 01 98 941 1010...
Страница 2: ......
Страница 43: ...41 Compool Cp 3830...