14
Compool Cp3830
1.
Run 2-conductor cables from spa and pool heater to the Power Center.
2.
At the heaters, connect 2-conductor cable as instructed in heater installation manual.
3.
At the Power Center circuit board, connect 2-conductor cables to the GAS HEATERS
terminals.
4.
If the heater has electronic ignition, provide high voltage power from the Sub-panel.
Water Temperature Sensors
The Water Temperature Sensors measure the pool and spa temperatures.
•
To wire the Water Temperature Sensors
1.
Select a convenient location to mount the sensors between the filter pump and filter.
2.
Drill a 5/16 inch diameter hole in the pipe and insert the sensors.
3.
Position the hose clamp over the sensors, and gently tighten around pipe.
Caution Do not overtighten clamp.
4.
Run a 2-conductor cable between each sensor and the Power Center.
5.
At the sensors, use crimp connectors (included) to provide waterproof connections.
Before making connections, cut off stripped ends of cable. Insert the 2 wires to be
connected into the connector and squeeze the connector with a pair of pliers. Two extra
connectors are included.
Caution Do not strip wires.
6.
At the Power Center circuit board, connect sensor wires to SPA WTR and POOL WTR
screw terminals. Pay attention to color-coding of wires.
Note Calibration of the Water Temperature Sensors is required. See Calibration for details.
POOL WATER SENSOR
RED
GRN
SPA WTR
POOL WTR
GRN
RED
GRN
RED
GRN
RED
GAS HEATERS
POOL SOL
SPA WATER SENSOR
RED
GRN
GRN
RED
FREEZE
SENSOR
POOL
SPA
SPA SOL
GRN
RED
TEMPERATURE SENSORS