38
Compool Cp3830
2-speed Spa Filter Pump Control
The 2-speed spa filter pump can be switched to high speed under the following conditions.
Heater/Solar is on.
AUX2 is on.
Note When the 2-speed filter is turned on, it will start in high speed and automatically switch
to low speed after 5 minutes.
2-speed Pool Filter Pump Control
The 2-speed pool filter pump can be switched to high speed under the following conditions.
Heater/Solar is on.
AUX1 is on.
Note When the 2-speed filter is turned on, it will start in high speed and automatically switch
to low speed after 5 minutes.
Spa Waterfall Control
The Spa Waterfall feature is similar to filling the spa. This feature uses Equipment key number
“2”. See Configuration Switches for details.
Freeze Protection
Where freezing temperatures occur for a few days, it is possible to protect equipment from
freeze damage by turning on pumps.
When the Freeze Temperature Sensor detects 35 degrees Fahrenheit or less, the system starts
Freeze Protection. An icon on the Control Panel will display FRZ to indicate that Freeze
Protection is active. Every 15 minutes the pool/spa valves will rotate to protect the spa
plumbing. When air temperature rises above 37 degrees Fahrenheit, the Freeze Protection mode
stops. See Configuration Switches to determine what equipment will turn on during Freeze
Protection.
Note Freeze Protection will not provide circulation of water through solar panels. Solar panels
must be protected by other methods. See Plumbing Requirements for details.
Winterizing the System
In areas where freezing temperatures occur for an extended period of time, it is required to
consult a qualified service company to winterize your pool.
Содержание Cp3830
Страница 1: ...Compool Cp3830 POOL SPA CONTROL SYSTEM Installation Operating Instructions 05 01 98 941 1010...
Страница 2: ......
Страница 43: ...41 Compool Cp 3830...