40
Compool Cp3830
Heat Source does not allow Solar
At the Power Center circuit board, the SYST configuration switch SSOL or PSOL needs
to be turned on. See Configuration Switches for details.
Solar heating stops too soon
Verify solar temperature is calibrated correctly. See Calibration for details.
Spa-side Remote does not operate
At the Control Panel, verify Remote Control at Spa lamp (behind right-side door) is turned
on.
No display at Control Panel
Check circuit breakers in the Sub-panel and Power Center.
Check communication cable.
Clock lost time after power failure
Replace battery located on Power Center circuit board.
System not responding
Reset the Control Panel. Locate small hole next to the Pool Temperature keys. With a
pointed object, push the reset button.
Reset the Power Center. Locate small hole next to Auto/Service key. With a pointed
object, push the reset button.
Determining revision date
At the Control Panel, press and hold the Enter key. The numbers on the left indicate the
Control Panel revision number, the numbers on the right indicate the Power Center
revision number.