Compool Cp3830
Configuration Switches
After setting configuration switches, turn system power off for a few seconds.
FREEZE
Freeze settings are used to configure the following equipment.
SFLT
Activate spa filter pump during freezing conditions.
PFLT
Activate pool filter pump during freezing conditions.
AUX1
Activate AUX1 during freezing conditions.
AUX2
Activate AUX2 during freezing conditions.
AUX3
Activate AUX3 during freezing conditions.
AUX4
Activate AUX4 during freezing conditions.
AUX5
Activate AUX5 during freezing conditions.
AUX6
Activate AUX6 during freezing conditions.
I/L - Interlock
Interlock settings are used to configure the following equipment.
FDEL
Activate filter delays (heater cool down).
CLNR
Activate cleaner interlocks. Cleaner must be installed on AUX1.
SYST - System
System settings are used to configure the following equipment.
MANHT
Activate heater when spa is manually turned on.
SSOL
Activate spa solar system.
SHPMP
Activate spa heatpump as secondary heat source.
PSSOL
Activate pool solar system.
PHPMP
Activate pool heatpump as secondary heat source.
FLRCL
Activate floor cleaner valve.
SPC FNCT - Special Functions
Special Functions settings are used to configure the following equipment.
DIM3
Activate dimmer for AUX3 circuit.
DIM4
Activate dimmer for AUX4 circuit.
B/W
Activate backwash circuit.
1
2
3
4
5
6
7
ON
8
1
2
3
4
5
6
7
ON
8
1
2
3
4
5
6
7
ON
8
SFLT
PFLT
AUX1
AUX2
AUX3
AUX4
AUX5
AUX6
FREEZE
I/L
SYST
SPC FNCT
FDEL
CLNR
MANHT
SSOL
SHPMP
PSOL
PHPMP
FLRCL
DIM3
DIM4
B/W
SHEAT
SAUX2
PHEAT
PAUX1
HI SPD