23
Compool Cp3830
To change spa command to pool heater, change the 2 jumpers, which are located at bottom of
the Power Center circuit board. Move both jumpers to POOL HEAT position.
•
To install the Telephone Module
1.
Install the Telephone Module into the low voltage compartment of the Power Center.
1.
Run a phone line to the Telephone Module.
2.
Connect the 4-wire interface cable from the Telephone Module into the PHONE socket at
the bottom of the Power Center circuit board.
Dimmer Relay
A maximum of two Dimmer Relays (model RLY-DIM) can be installed. These relays are
controlled by Equipment keys 3 and 4. Each relay can switch a maximum of 1000 watts.
•
To install the Dimmer Relay
1.
Install the Dimmer Relay(s) into high the voltage compartment.
2.
Plug the control wire(s) into DIM 3 and/or DIM 4 sockets.
3.
Turn on SPC FNCT configuration switch DIM3 and/or DIM4 located at bottom of the
Power Center circuit board.
Backwash Control
The backwash control system is designed to automatically backwash the pool filter on a timed
basis. This feature uses the B/W circuit to control the two backwash valves.
To install an automatic backwash system, you must have a sand filter with a side inlet and outlet.
The following additional equipment is required, one Valve Module (model MOD-VLV3), three
Valve Actuators (model CVA-24T), and three 3-port valves (model PTV-2T).
•
To install the Backwash Control
1.
Connect a jumper wire between the B/W socket and the Valve Module CONTROL
JUMPERS socket. Turn on D.I.P. switch number 1 and 2 on the Valve Module.
2.
Connect backwash Valve Actuator cords into VLV, VLV2, and VLV3 sockets on the Valve
Module.
3.
Turn on SPC FNCT configuration switch B/W located at the bottom of the Power Center
circuit board.
4.
Program the backwash interval and duration times at the Control Panel. See Calibration
for details.
Floor Cleaner Valve
The Floor Cleaner Valve is designed to control a dual zone floor cleaning system. The Floor
Cleaner Valve can be programmed to rotate once every 5-60 minutes while the pool filter pump
is on. Additional parts required, one Valve Actuator (model CVA-24T), and one 3-port valve
(model PTV-2T).
•
To install the Floor Cleaner Valve
1.
Install Valve Actuator onto Floor Cleaner valve.
Содержание Cp3830
Страница 1: ...Compool Cp3830 POOL SPA CONTROL SYSTEM Installation Operating Instructions 05 01 98 941 1010...
Страница 2: ......
Страница 43: ...41 Compool Cp 3830...