Compool

Cp3830 POOL-SPA CONTROL SYSTEM

Installation & Operating Instructions

05/01/98
941-1010

Содержание Cp3830

Страница 1: ...Compool Cp3830 POOL SPA CONTROL SYSTEM Installation Operating Instructions 05 01 98 941 1010...

Страница 2: ......

Страница 3: ...oltage Wiring 12 Power Center Circuit Board 12 Low Voltage Cables 13 Gas Heater Connections 13 Water Temperature Sensors 14 Freeze Temperature Sensor 15 Control Panel 16 Modular Crimping Tool 17 Syste...

Страница 4: ...Programming 30 Programming 31 Programming additional Run Times 31 Programming a Time out 31 Programming a Once only 32 Canceling Programs 32 Setting the Time of Day 32 Remote Control at Spa key 32 Ca...

Страница 5: ...unless they are closely supervised at all times Water in excess of 100 degrees Fahrenheit may be hazardous to your health A terminal bar marked for equipment ground only is located inside the high vol...

Страница 6: ...4 Compool Cp3830 Introduction Package Contents The CP3830 S system includes the following components CP 3830 Control Panel w cable 1 qty LX 3830 Power Center 1 qty SNS KIT3 Sensor Kit 1 qty...

Страница 7: ...5 Compool Cp3830 The CP3830 SL system includes the following components CP 3830 Control Panel w cable 1 qty LX 3830L Power Center 1 qty SNS KIT3 Sensor Kit 1 qty...

Страница 8: ...and return lines between the filter and heater Install 3 port solar valve at the feed line Use Compool solar valve model SOL 2T to allow automatic draining of panels 4 Glazed solar panels require a dr...

Страница 9: ...water to a waterfall This eliminates the need for an additional pump Equipment Location With the exception of the Spa side Remote all equipment must be located at least 10 from the water s edge Locat...

Страница 10: ...the equipment Provide power from the Main panel located at the house to Power Center Power Center without built in Sub panel At the equipment pad mount a 100 amp electrical circuit breaker panel Sub p...

Страница 11: ...er The system draws less than 1 amp Do not use a GFCI circuit breaker 2 Run appropriate wires from the circuit breaker to the System Power terminal block 3 For a 115 volt connection connect to termina...

Страница 12: ...P install an external contactor Use relay to switch coil of external contactor Adding Relays The Power Center comes standard with 4 relays It is possible to add additional relays model RLY LX The LX 3...

Страница 13: ...e light to LOAD 1 of the relay terminal block 5 Connect a wire from LINE 1 of the relay terminal block to the LOAD SIDE of the GFCI receptacle Note The example above assumes the pool or spa light is 5...

Страница 14: ...18 10 24 PART PC LX3830 COMPOOL 11010B SPA 2SPD SFLT PFLT AUX1 AUX2 AUX3 AUX4 AUX5 AUX6 FREEZE I L SYST SPC FNCT FDEL CLNR MANHT SSOL SHPMP PSOL PHPMP FLRCL DIM3 DIM4 B W SHEAT SAUX2 PHEAT PAUX1 DIM3...

Страница 15: ...tween the pool Water Temperature Sensor and the Power Center Freeze Temperature Sensor 2 conductor runs between the Freeze Temperature Sensor and the Power Center Caution Do not install low voltage an...

Страница 16: ...clamp over the sensors and gently tighten around pipe Caution Do not overtighten clamp 4 Run a 2 conductor cable between each sensor and the Power Center 5 At the sensors use crimp connectors included...

Страница 17: ...ed into the connector and squeeze the connector with pliers Two extra connectors are included Caution Do not strip wires 4 At the Power Center circuit board connect sensor wires to FREEZE SENSOR screw...

Страница 18: ...nts Insert mounting anchors included into the three holes 4 Pull cable through large hole in backplate use the three 1 25 screws to mount backplate to wall Use crimping tool to connect modular connect...

Страница 19: ...ng from an electrical supply store verify it is designed to crimp 6 position connectors To install the modular connectors 1 Use stripper to remove cable jacket 2 Insert modular connector into crimper...

Страница 20: ...c pipe with pvc cement so that the red button will be on top 5 At the Power Center connect Spa side Remote wires to appropriate screw terminals located at bottom of the of the circuit board 6 Connect...

Страница 21: ...being wired where each communication cable is run back to the Power Center a coupler model 6COND DUAL is required Valve Actuator The Valve Actuator comes with 15 feet of cable If this distance is not...

Страница 22: ...wire into the Power Center circuit board at the appropriate relay socket SPA FLTR POOL FLTR AUX1 AUX2 AUX3 AUX4 AUX5 AUX6 B W SPA EHTR SPA SOL POOL EHTR POOL SOL SPA 2SPD FLR CLR and POOL 2SPD 6 The D...

Страница 23: ...te SYST configuration switch SSOL and or PSOL located at the bottom of the Power Center circuit board 6 Connect solar Valve Actuator cord into AUX VLV socket at the Power Center circuit board Connect...

Страница 24: ...ol filter pump install a 2 speed relay kit model RLY LXD into Power Center There are two ways to configure the pool 2 Speed filter pump Automatic configuration The system will run the filter pump in l...

Страница 25: ...lter on a timed basis This feature uses the B W circuit to control the two backwash valves To install an automatic backwash system you must have a sand filter with a side inlet and outlet The followin...

Страница 26: ...r Center circuit board 3 Connect a jumper wire between the AUX VLV CNTRL and the FLR CLN sockets 4 Turn on SPC FNCT configuration switch FLRCL located at the bottom of Power Center circuit board 5 Pro...

Страница 27: ...EL Activate filter delays heater cool down CLNR Activate cleaner interlocks Cleaner must be installed on AUX1 SYST System System settings are used to configure the following equipment MANHT Activate h...

Страница 28: ...eys verify heaters fire Filter pumps must also be on 4 Press the Solar keys verify solar valves if applicable rotate to solar position If either valve is 180 degrees out of phase flip the toggle switc...

Страница 29: ...as needed Equipment Keys Equipment keys activate the Spa Pool and up to 6 additional items Each key can be custom labeled for your specific application To turn equipment on or off press the appropria...

Страница 30: ...e spa or pool is turned off the system may keep the filter pump on for an additional 10 minutes to allow the heater to cool down During this cool down cycle and icon on the display will indicate DELAY...

Страница 31: ...o heating For added convenience whenever the spa is manually activated from either the Control Panel or the Spa side Remote the Spa Heat Source Lamp will automatically switch to Heater Turning the spa...

Страница 32: ...ey Located behind the right door of the Control Panel is the Temp Display key Press this key to select Fahrenheit or Celsius temperature display Programming Behind the right door of the Control Panel...

Страница 33: ...additional Run Times It is possible to program up to four separate START TIME and RUN TIME s for each equipment key Follow the previous example to step 2 then press the same equipment key until PROG...

Страница 34: ...keys 2 Press and hold down the Cancel key for 5 seconds After 5 seconds a continuous alarm will sound until you release the Cancel key indicating that all of the programs have been erased 3 Press the...

Страница 35: ...Program key 2 Press the Spa Heat Source key 3 Enter correct pool water temperature and press Spa Heat Source key 4 Enter correct pool solar temperature and press Spa Heat Source key 5 Enter correct s...

Страница 36: ...wash and floor cleaner valve adjustments are skipped if feature is not enabled Tips for calibrating the temperature sensors Water Sensors Let the spa and pool run for 5 minutes to allow water temperat...

Страница 37: ...er door after use The Auto Service key toggles the Power Center between the following modes Auto Control Panel and Spa side Remote are enabled Power Center keys are disabled Service Power Center keys...

Страница 38: ...y circuits for a 3 Hour period This is particularly useful when adding chemicals to the pool Note The Control System must be in Auto mode to enable these feature To turn the filter pump on press the P...

Страница 39: ...icate that the spa is no longer being heated Telephone Module The Telephone Module can control your equipment from inside your home or by calling your home from a remote location The Telephone Module...

Страница 40: ...Protection Where freezing temperatures occur for a few days it is possible to protect equipment from freeze damage by turning on pumps When the Freeze Temperature Sensor detects 35 degrees Fahrenheit...

Страница 41: ...eze Temperature Sensor model TS 5L Display shows Err 4 If the Control Panel is not able to communicate with the Power Center the display will show Err 4 Check communication cable and connections Use t...

Страница 42: ...Panel Check circuit breakers in the Sub panel and Power Center Check communication cable Clock lost time after power failure Replace battery located on Power Center circuit board System not responding...

Страница 43: ...41 Compool Cp 3830...

Страница 44: ...er 10 Equipment Status Icons 27 Equipment Status Lamps 28 Fahrenheit Celsius key 30 Floor Cleaner Valve 23 FREEZE 25 Freeze Protection 38 Freeze Temperature Sensor 15 Gas Heater Connections 13 Heat Pu...

Страница 45: ...Day 32 Solar Booster Pump Control 21 Solar Heating 21 Spa Waterfall Control 38 Spa side Heat Boost 37 Spa side Remote 18 Spa side Remote 37 SPC FNCT Special Functions 25 SYST System 25 System Options...

Отзывы: