Installation
3-29
Compaq Confidential – Need to Know Required
Writer: Everett Godaire Project: TL891 MiniLibrary System User's Guide Comments:
Part Number: ER-TL891-UA.A01 File Name: d-ch3 Installation Last Saved On: 3/2/99 2:30 PM
SHR-1197
5
1
4
3
2
Figure 3-15. Expansion Unit SCSI Connectors and Cables (Fast/Wide SCSI
Shown)
1
Pass-Through Mechanism
Motor Cable
4
SCSI Cable
2
Power Cable
5
Diagnostic Connector
3
Robotics Cables To Base
Modules
Pass-Through Mechanism Motor Cable
The pass-through mechanism motor cable is 36 inches long and has a male
DB-15 connector on each end. Connect the cable from the connector on the
motor housing to the elevator connector on the Expansion Unit.
Control Cables
Connect each Base Module to the Expansion Unit using one of the cables with
a DB-9 male connector at the base end and a DB-9 female at the Expansion
Unit end. A cable is required for each Base Module.
NOTE:
Any of the control cables may be connected to any of the DB-9 connectors on the
back panel of the Expansion Unit. The Expansion Unit determines the location of each
module during power-up tests.