6-26
TL891 MiniLibrary System User's Guide
Compaq Confidential – Need to Know Required
Writer: Everett Godaire Project: TL891 MiniLibrary System User's Guide Comments:
Part Number: ER-TL891-UA.A01 File Name: g-ch6 Diagnostics and Troubleshooting Last Saved On: 3/3/99 11:54 AM
Of these selections, only Cartridge Cycle is intended for use in the field. The
remaining tests are used during factory setup.
Cartridge Cycle Diagnostic
When you select Cartridge Cycle, the library robotics begin to move cartridges
randomly from slot to slot in the magazine, while reporting on the front panel
the number of passes.
This diagnostic will run continuously as long as the Base Module has power.
To stop the test, press the Escape button. A flashing message appears on the
display telling you that the test is paused. Pressing the Escape button a second
time terminates the diagnostic and returns to the Maintenance Menu.
Using the Demo Submenu
The only User Diagnostic is found on the Demo submenu on the Maintenance
Menu. The submenu lists five demos, numbered 1 through 5. At present, only
Demo 1 is implemented. Demo 1 enables the user to fully exercise the library
robotics.
When you select Demo 1, the library robotics begins to move cartridges
randomly from slot to slot in the magazine, while reporting on the front panel
the number of passes. If all ten slots in the magazine are full, Demo 1 will load
a cartridge into DLT0 and leave it there. If you press the
button while
Demo 1 is running, the system will load a cartridge into DLT0, unless DLT0 is
full. If you press the
button again, the cartridge is unloaded from DLT0 and
returned to the magazine. The
button causes DLT1 to be loaded and
unloaded in the same way.
Demo 1 will run continuously as long as the Base Module has power. To stop
the test, press the Escape button. A flashing message appears on the display
telling you that the test is paused. Pressing the Escape button a second time
terminates Demo 1 and returns to the Maintenance Menu.