4-8
TL891 MiniLibary System User's Guider
Compaq Confidential – Need to Know Required
Writer: Everett Godaire Project: TL891 MiniLibary System User's Guider Comments:
Part Number: ER-TL891-UA.A01 File Name: e-ch4 Configuration Last Saved On: 3/1/99 2:15 PM
Custom and press
Enter
to accept this setting. To return the module to online
status, press
Escape
three times.
Set Element Base
This option allows you to set the base addresses of each of the three SCSI
elements of the module. In order to identify sources and destinations in
commands to the robotics, the base module is divided into elements, each of
which is assigned a separate designator or element address. The Transport
Element is the robotics mechanism itself; the Storage Elements are the 10 slots
in the magazine; the Transfer Elements are the drives. The Base Module
reports these settings in response to the SCSI Mode Sense command, in the
Element Address Assignment Page. The defaults are Transport = 0000h,
Storage element base = 0001h, Transfer element base = 00F0h.
Set Date
Enables you to set the module’s calendar.