Table 6-2
Fault Symptom Codes
continued
FSC
Message
Description
6043
Invalid Com Blk Type
A Slave inter-module process received
a packet from the Master inter-module
process, but the packet’s CommBlock
type was invalid.
6044
Invalid Com Blk Type
A Slave inter-module process received
a packet from the Status/Message
queue, but the packet’s CommBlock
type was invalid.
6045
Command Overlap
A Slave inter-module process received
a Command from the Master inter-
module process, but a previously
issued command is still being
executed.
6046
No Pkts To Send
A Slave inter-module process has
been requested to send a packet to
the Master inter-module process, but
the Slave inter-module process has no
packets to send.
6047
Invalid Direction
A Slave inter-module process has
received a direction control byte from
the Master inter-module process, but
the direction control byte is invalid.
6048
Master Pkt ID Bad
B001
Boot ROM CRC Error
B002
Boot RAM Test Failed
B004
Boot Comm Open Error
B005
Boot Novram Error
B006
Boot Unused Int
B007
Flash Init Error
B010
Boot UART 0 Error
continued