1-12
Introduction
For use with Intel Pentium II Xeon processor-based servers only
Writer: Salvo Project: Compaq ProLiant 5500 Servers Setup and Installation Guide Comments: 328470-001/July 1998
File Name: B-CH01.DOC Last Saved On: 7/6/98 3:56 PM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
IMPORTANT:
This server is not equipped with chassis interlocks. There are
board interlocks that connect the memory board, processors, peripheral
board and power switch cable into one interlock chain.
When one of the connected components in the interlock chain is improperly
seated in the connector, the LED associated with the fault origination point will
illuminate. See Table 1-1 and Figure 1-1 for details regarding the interlock
error.
Table 1-1
LED Labels
Memory
CPU4
CPU3
CPU2
CPU1
I/O
Fault
Origination
ON
ON
ON
ON
ON
ON
Memory
Board
OFF
ON
ON
ON
ON
ON
Processor 4
OFF
OFF
ON
ON
ON
ON
Processor 3
OFF
OFF
OFF
ON
ON
ON
Processor 2
OFF
OFF
OFF
OFF
ON
ON
Processor 1
OFF
OFF
OFF
OFF
OFF
ON
Peripheral
Board
OFF
OFF
OFF
OFF
OFF
OFF
No
interlock
error
NOTE
: Only the left-most illuminated LED in any given row can provide a valid
indication of the interlock error. After ensuring that server is powered down and
power cables are disconnected, reseat the device associated with the left-most
illuminated LED.