7-21
Compaq ProLiant 5500 Servers Setup and Installation Guide
For use with Intel Pentium II Xeon processor-based servers only
Writer: Salvo Project: Compaq ProLiant 5500 Servers Setup and Installation Guide Comments: 328470-001
File Name: H-CH07.DOC Last Saved On: 7/13/98 11:24 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
SCSI Cable Usage Matrix for Duplex Mode
Continued
Controller
Smart-2 Array
Controller /SL,
/P, /DH , and
Smart Array
3200 Controller
Without
Loopback SCSI
Option
Hot-Plug SCSI Hard
Drives in Internal
Drive Cage
■
Use cable option
kit 306585-B21.
■
Connect 19-inch
point-to-point non-
terminated SCSI
cable (199606-
007) from optional
controller board to
SCSI Input 0 of
duplex board.
or
■
Use second SMART
or Smart Array
3200 Controller
and additional
cable option kit.
■
Connect a second
19-inch point-to-
point non-
terminated SCSI
cable (199606-
007) from SCSI
port 1 or 2 of
integrated SCSI
controller to Input
1 of duplex board.
2/4 DAT Drive
4/8 DAT Drive
Internal TurboDAT
Autoloader
8X SCSI CD-ROM
4/16 TurboDAT
15/30 DLT Drive
Tape Drives and CD-
ROMs are
not supported
using a SMART-2 Array
Controller
35/70 DLT Drive
Tape Drives and CD-
ROMs are
not
supported using a
SMART-2 Array
Controller
Continued
Содержание ProLiant 5500
Страница 8: ......