7-20
Cabling
For use with Intel Pentium II Xeon processor-based servers only
Writer: Salvo Project: Compaq ProLiant 5500 Servers Setup and Installation Guide Comments: 328470-001
File Name: H-CH07.DOC Last Saved On: 7/13/98 11:24 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
SCSI Cable Usage Matrix for Duplex Mode
continued
Controller
Hot-Plug SCSI Hard
Drives in Internal Drive
Cage
2/4 DAT Drive
4/8 DAT Drive
Internal TurboDAT
Autoloader
8X SCSI CD-ROM
4/16 TurboDAT
15/30 DLT Drive
35/70 DLT Drive
32 Bit Fast-
Wide SCSI-2
Controller /P
and Wide-Ultra
Controller/P
■
Use cable option
kit 306585-B21.
■
Connect 19-inch
point-to-point non-
terminated SCSI
cable (199606-
007) from optional
controller board to
SCSI Input 0 of
duplex board.
■
Connect a second
19-inch point-to-
point non-
terminated SCSI
cable (199606-
007) from SCSI
port 1 or 2 of
integrated SCSI
controller to Input
1 of duplex board.
or
■
Use second 32 bit
fast-wide controller
and additional
cable option kit.
■
Use cable option kit
306585-B21.
■
Connect 32-inch
3-device non-
terminated SCSI
cable (199616-012)
from optional
controller board to
removable media
bay devices.
■
Use 50 to 68 pin
adapter (199618-
001), if needed.
■
Use cable
option kit
306585-B21.
■
Connect 32-
inch 3-device
non-terminated
SCSI cable
(199616-012)
from optional
controller board
to removable
media bay
devices.
Continued
Содержание ProLiant 5500