background image

1-8

    

Introduction

For use with Intel Pentium II Xeon processor-based servers only

Writer: Salvo   Project: Compaq ProLiant 5500 Servers Setup and Installation Guide   Comments: 328470-001/July 1998

File Name: B-CH01.DOC   Last Saved On: 7/6/98 3:56 PM

COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED

Automatic Server Recovery-2 (ASR2)

If there is a critical system failure, Automatic Server Recovery-2 allows you to
restart the server and page a designated system administrator. For more
information, see the Compaq Server Online Reference Guide on the Systems
Reference Library CD (SRL).

Security Features

■ 

Power-on password

■ 

Administrator password

■ 

Network server mode

■ 

Diskette boot control

■ 

Physically protected power switch

■ 

Serial/parallel interface control

■ 

Remote access password

■ 

Front bezel lock (tower model only)

Refer to the Compaq Server Online Reference Guide on the Systems Reference
Library (SRL) CD for more information on these security features.

Содержание ProLiant 5500

Страница 1: ...ProLiant 5500 Setup and Installation Guide For Intel Pentium II Xeon Processor based Servers First Edition July 1998 Part Number 328470 001 Compaq Computer Corporation...

Страница 2: ...n consent from Compaq Computer Corporation 1998 Compaq Computer Corporation All rights reserved Printed in the U S A The software described in this guide is furnished under a license agreement or nond...

Страница 3: ...ntation xiii Getting Help xiv Starting the Documentation after Installation xiv Ordering Printed Documentation or Additional CDs xiv Ordering Electronically xiv Ordering by Fax xv Text Conventions xv...

Страница 4: ...t 1 13 Chapter 2 Installation Overview Server Warnings and Precautions 2 2 Pre installation Planning 2 3 Power Requirements 2 3 Grounding 2 4 Server Temperature Requirements 2 4 Installation Procedure...

Страница 5: ...2 System Board Features 4 11 System Board Switches 4 12 Interlock System 4 15 Accessing the Drive Cage Back Plane 4 15 Accessing Hot Plug Areas 4 21 Accessing the Hot Plug SCSI Drives 4 21 SCSI ID Nu...

Страница 6: ...ns 6 10 Display Symbols 6 11 System Behavior with Error Events 6 12 Menu Structure 6 13 Integrated Management Log 6 14 Multiple Ways of Viewing the Log 6 15 List of Events 6 18 Error Code Messages 6 2...

Страница 7: ...dia Bay 7 24 Appendix A Regulatory Compliance Notices Federal Communications Commission Notice A 1 Class B Equipment A 1 Declaration of Conformity for Products Marked with FCC Logo United States Only...

Страница 8: ......

Страница 9: ...the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels WARNING There is a risk of personal injury from hazardous energy levels The installation...

Страница 10: ...eps to install the electronic documentation Close all other applications before installing Your documentation CD can be installed on any system meeting these minimum requirements 486 processor or fast...

Страница 11: ...Documents later in this chapter The Compaq Server Documentation program group and Compaq ProLiant 5500 Documentation icon will be created in your system You must leave the CD in the CD ROM drive to a...

Страница 12: ...ent Click On Instructions for installation and reference for operation and future Compaq ProLiant 5500 Setup and Installation Guide Setup and Install Instructions for installing and using the Integrat...

Страница 13: ...the same text select Tools and then Find Again Using the Linked Table of Contents Once you open a document you can link to a topic from the table of contents Click on the topic you want If a contents...

Страница 14: ...he Compaq ProLiant 5500 Documentation icon Ordering Printed Documentation or Additional CDs A set of printed documents on the CD is available The set contains Compaq ProLiant 5500 Setup and Installati...

Страница 15: ...ts of text Keys Keys appear in boldface A plus sign between two keys indicates that they should be pressed simultaneously USER INPUT User input appears in a different typeface and in uppercase FILENAM...

Страница 16: ...ying information or specific instructions NOTE Presents commentary sidelights or interesting points of information Symbols on Equipment These icons may be located on equipment in areas where hazardous...

Страница 17: ...mponent allow the surface to cool before touching WARNING Power Supplies or Systems marked with these symbols indicate the equipment is supplied by multiple sources of power WARNING To reduce the risk...

Страница 18: ...ether in multiple rack installations A rack may become unstable if more than one component is extended for any reason Extend only one component at a time This guide is designed to be used as step by s...

Страница 19: ...Last Saved On 7 14 98 9 33 AM Telephone Numbers For the name of your nearest Compaq Authorized Reseller In the United States call 1 800 345 1518 In Canada call 1 800 263 5868 For Compaq technical supp...

Страница 20: ...tel Pentium II Xeon Processors dual peer PCI buses and up to four gigabytes of buffered EDO ECC memory Input output performance is enhanced by features such as Wide Ultra SCSI 3 hard drives Compaq Pro...

Страница 21: ...ach bank must have four DIMMs of the same size and speed Expansion Slots Seven I O expansion slots Six 32 bit PCI slots one is populated with a Compaq Netelligent 10 100 TX PCI UTP Controller One shar...

Страница 22: ...see www compaq com for updates on device support Smart Array 3200 Controller SMART 2DH Array Controller Wide Ultra SCSI 3 Controller Video Integrated PCI Video Controller provides maximum resolution o...

Страница 23: ...timely server environment and subsystem information by using a combination of hardware firmware and industry standard management software Information provided by this utility includes fault performanc...

Страница 24: ...xtensive set of features and optional tools to support effective server management and configuration These features are described in this guide SmartStart and Support Software CD Fault Tolerance Compa...

Страница 25: ...ts a Windows based console application and server or client based management data collection agents Starting with Compaq Insight Manager 4 0 the agents for Windows NT and Netware are also web enabled...

Страница 26: ...es effective deployment and maintenance of consistent manageable configurations with Insight Version Control and Integration Server Maintenance Performance management resource utilization helps the us...

Страница 27: ...ows you to restart the server and page a designated system administrator For more information see the Compaq Server Online Reference Guide on the Systems Reference Library CD SRL Security Features Pow...

Страница 28: ...roLiant 5500 server is equipped with an optional supported modem you can perform a wide range of configuration activities using the standard Compaq Integrated Remote Console IRC The IRC Is accessible...

Страница 29: ...is standard on rack models and optional on tower models The features of the Integrated Management Display include Flexibility The Integrated Management Display rotates to support both tower and rack c...

Страница 30: ...figuration optimizing performance and storage could include the following One network interface controller NIC Six Smart Array 3200 Controllers or SMART 2DH Controllers Twelve Compaq ProLiant Storage...

Страница 31: ...the connector the LED associated with the fault origination point will illuminate See Table 1 1 and Figure 1 1 for details regarding the interlock error Table 1 1 LED Labels Memory CPU4 CPU3 CPU2 CPU...

Страница 32: ...h an Authorized Compaq Reseller Supported components are eligible for replacement under this warranty before they actually fail if the system determines that these components have degraded below prede...

Страница 33: ...for Compaq ProLiant 5500 servers You are referred to later chapters in this guide for detailed discussions of rack installation hardware option installation and configuration Topics in this chapter i...

Страница 34: ...e connecting the power cord to the power supply Unplug the power cord before removing the power supply from the server If the system has multiple power supplies disconnect power from the system by unp...

Страница 35: ...onsult the electrical authority having jurisdiction over your facility wiring and installation requirements The power load needs to be balanced between available AC supply branch circuits The overall...

Страница 36: ...nt is required to be properly grounded in accordance with NFPA 70 1993 Article 250 All power distribution devices branch wiring and receptacles must be Listed grounding type devices When using power s...

Страница 37: ...roLiant 5500 server Select an appropriate site for your rack See the Rack Planning and Installation Guide on the Compaq Installing Rack Products CD for site selection criteria Make sure that stabilize...

Страница 38: ...nd Support Software program has finished configuring your system you have completed the installation of your new Compaq server Installing a Tower Model Below are the general steps for installing your...

Страница 39: ...ents 328470 001 July 1998 File Name C CH02 DOC Last Saved On 7 6 98 10 37 AM For complete details on the SmartStart and Support Software program read the SmartStart and Support Software installation c...

Страница 40: ...amage to the equipment at least two people are needed to safely unload the rack from the pallet An empty 42U rack weighs 253 lb 115 kg is over seven ft 2 1 m tall and may become unstable when being mo...

Страница 41: ...rack be sure that the leveling jacks are extended to the floor that the full weight of the rack rests on the level floor and that either stabilizers are installed or that multiple racks are coupled t...

Страница 42: ...he warm air to escape from the cabinet Do not block the ventilation apertures CAUTION If a third party rack is used the following minimum requirements should be observed to ensure adequate airflow and...

Страница 43: ...untable server Optional Installation Service The installation service covers the entire hardware installation from unpacking the servers to routing the cables and running a test of the system In the U...

Страница 44: ...ant 5500 Servers Setup and Installation Guide Comments 328470 001 July 1998 File Name D CH03 DOC Last Saved On 7 6 98 4 04 PM Locating Materials and Documentation All of the equipment needed to instal...

Страница 45: ...rver Cables Rack mounting hardware numbers reference Figure 3 1 One pair 26 inch slide rail assemblies One pair slide rail mounting brackets Cable management arm server bracket Cable management arm Mo...

Страница 46: ...Rack configurations based on your input Rack Builder provides the information such as Graphical preview of properly configured racks Site planning data including power requirements cooling mandates a...

Страница 47: ...etc Integrated Management Display tower model only Array Controller Redundant fans Preparing the Mounting Brackets and Slide Rail Assemblies Each pair of mounting brackets with attached slide rail as...

Страница 48: ...efore attaching the mounting bracket assembly to the rack This way the joined mounting bracket and bracket rail can be fastened to the rack as one assembly Attaching the Bracket Rail to the Mounting B...

Страница 49: ...998 File Name D CH03 DOC Last Saved On 7 6 98 4 04 PM Figure 3 4 Removing the server rail from the bracket rail 2 Put the server rails to one side You will attach them to the rack server chassis later...

Страница 50: ...ket and an inner slide on a steel ball bearing movement This inner slide does not detach Figure 3 6 Bracket rail with inner slide The front of the rail is highlighted 3 Lay the bracket rail inside the...

Страница 51: ...the bracket rail to the mounting bracket with two 8 32 x 1 4 inch slotted screws Do not use nuts or washers with the screws See step of the following figure 6 Adjust the inner slide to access the othe...

Страница 52: ...2 3 26 2 2 Figure 3 7 Attaching the bracket rail to the mounting bracket You will use a total of four 8 32 x 1 4 inch slotted screws to fasten the bracket rail to the mounting bracket When all four sc...

Страница 53: ...y and reliable way to properly position the server in the rack Use the tabs on the template to suspend it from the lower hole of a two hole set of perforations in the vertical side rails Pencil mark t...

Страница 54: ...or the thumbscrews that will secure the server s face plate to the front of the rack Align the template carefully with the holes on the rack to determine the exact placement of the screws 2 When you m...

Страница 55: ...ack to access the back rails 4 On the back of the rack also mark the rail to show the top of the template This will help you align a template for the next server Inserting Cage Nuts in the Rack Frame...

Страница 56: ...8 4 04 PM 3 Insert the tip of the fitting tool through the other side of the perforation and hook the opposite lip of the cage nut Figure 3 9 Inserting cage nuts 4 Using the fitting tool as a lever pr...

Страница 57: ...12L Phillips screw in the bottom hole of the bracket Do not use the washers supplied with the Compaq rack IMPORTANT Use only the bottom hole of the bracket as shown in Figure 3 10 Figure 3 10 Attachi...

Страница 58: ...ct Compaq ProLiant 5500 Servers Setup and Installation Guide Comments 328470 001 July 1998 File Name D CH03 DOC Last Saved On 7 6 98 4 04 PM CZR4 012 eps Top View Figure 3 11 Cage nut and back of moun...

Страница 59: ...e Name D CH03 DOC Last Saved On 7 6 98 4 04 PM Attaching Server Rails 1 Place the tab on a server rail at the front of the server chassis The holes in the server rail will line up only one way with th...

Страница 60: ...Bracket As viewed from the rear of the server the cable management arm server bracket fastens to the top left rear of the rack server s chassis The bracket provides an attachment point for the cable...

Страница 61: ...ackets is perfectly aligned and installed and that the server fits before you continue WARNING To reduce the risk of personal injury or damage to the equipment a minimum of two people MUST lift the se...

Страница 62: ...1998 File Name D CH03 DOC Last Saved On 7 6 98 4 04 PM 1 Pull the slide rails forward from the mounting brackets 2 Carefully align the server s server rails with the rack s slide rails and slide the...

Страница 63: ...time the ball bearings in the slide will move easily IMPORTANT When servicing the server fully extend the server until the latches lock To return the server to the rack depress the latches and slide t...

Страница 64: ...ng the server in the rack the arm may swing around and interfere with the loading process 2 After you have loaded the server into the rack attach one end of the cable management arm to the server s ca...

Страница 65: ...e Comments 328470 001 July 1998 File Name D CH03 DOC Last Saved On 7 6 98 4 04 PM Figure 3 16 Attaching the cable management arm to the rear brace of the rack 4 Attach and secure external cables for k...

Страница 66: ...er cord s from the power supplies in order to install options upgrades or replacements in the following areas Intel Pentium II Xeon Processors Memory board and sockets System board Peripheral board Dr...

Страница 67: ...l power cords from either the electrical outlet or the server WARNING To reduce the risk of electric shock or damage to the equipment Do not disable the power cord grounding plug The grounding plug is...

Страница 68: ...he electrical outlet IMPORTANT The system power in the ProLiant 5500 server does not completely shut off with the front panel Power On Standby switch The two positions of the switch function as ON and...

Страница 69: ...st Saved On 7 13 98 8 13 AM 7 Slide the side cover toward the rear of the unit about 1 inch 2 5 cm then remove the cover Figure 4 1 Removing the server cover Accessing the Processor The ProLiant 5500...

Страница 70: ...ed On 7 13 98 8 13 AM 1 To add a processor identify the processor locations as shown in Figure 4 2 NOTE Processors can be installed in any processor socket All four processor sockets must have either...

Страница 71: ...ation Guide Comments 328470 001 July 1998 File Name E CH04 DOC Last Saved On 7 13 98 8 13 AM 1 2 2 3 Figure 4 3 Removing the terminator board 3 See Figure 4 4 below for processor installation procedur...

Страница 72: ...processor based servers only Writer Salvo Project Compaq ProLiant 5500 Servers Setup and Installation Guide Comments 328470 001 July 1998 File Name E CH04 DOC Last Saved On 7 13 98 8 13 AM 1 2 3 4 Fi...

Страница 73: ...vo Project Compaq ProLiant 5500 Servers Setup and Installation Guide Comments 328470 001 July 1998 File Name E CH04 DOC Last Saved On 7 13 98 8 13 AM Accessing DIMM Sockets on the Memory Board 1 Power...

Страница 74: ...500 Servers Setup and Installation Guide Comments 328470 001 July 1998 File Name E CH04 DOC Last Saved On 7 13 98 8 13 AM 3 Install DIMMs as shown in Figure 4 8 For information on memory banks see the...

Страница 75: ...In the Compaq ProLiant 5500 server the Memory board is grouped into 4 banks where 1 bank is 2 DIMMs adjacent to 2 other DIMMs as shown below for bank 1 When memory is added you must add 1 bank at a ti...

Страница 76: ...4 5 6 7 8 9 13 15 23 11 17 18 22 21 20 19 10 14 16 12 Figure 4 11 System board features Table 4 1 System Board Features Identifier Description Identifier Description 1 Shared PCI ISA slots i Floppy po...

Страница 77: ...s been shipped with the core frequency switch properly set However you may consider changing the core frequency switch setting when upgrading to a faster processor CAUTION Data integrity may be compro...

Страница 78: ...re 4 12 Peripheral Board Features Table 4 3 Peripheral Board Features Identifier Description Identifier Description 1 Fan cable assembly connector 9 Integrated Management Display connector 2 Power swi...

Страница 79: ...ration Switch Switch Open Off Position Closed On Position 1 Video Enable integrated video Disable integrated video 2 Lock Configuration Configuration can be changed Configuration can not be changed 3...

Страница 80: ...in one interlock chain When one of the connected components in the interlock chain is improperly seated in the connector the LED associated with the fault origination point will illuminate See Chapter...

Страница 81: ...le Name E CH04 DOC Last Saved On 7 13 98 8 13 AM 1 2 Figure 4 13 Removing a fan 3 Unlock the server open the front panel and slide the front panel up and away from the server Figure 4 14 Removing fron...

Страница 82: ...t Compaq ProLiant 5500 Servers Setup and Installation Guide Comments 328470 001 July 1998 File Name E CH04 DOC Last Saved On 7 13 98 8 13 AM Figure 4 15 Partially pull out the drive cage Figure 4 16 D...

Страница 83: ...he steps under Accessing the Drive Cage Back Plane before proceeding with the following steps 1 Remove any components in the removable media bays and install them into the duplex drive cage 2 Replace...

Страница 84: ...Comments 328470 001 July 1998 File Name E CH04 DOC Last Saved On 7 13 98 8 13 AM 3 Reconnect the SCSI cables on the back of the drive cage Refer to Figure 4 18 for connector identification See Chapter...

Страница 85: ...H04 DOC Last Saved On 7 13 98 8 13 AM 4 Pull out the drive cage latch and push the drive cage back fully until the drive cage latch can be pushed into place 5 Tighten the thumbscrews on the front of t...

Страница 86: ...328470 001 July 1998 File Name E CH04 DOC Last Saved On 7 13 98 8 13 AM Accessing Hot Plug Areas This section describes how to access the hot plug SCSI drive area Components in these areas have color...

Страница 87: ...File Name E CH04 DOC Last Saved On 7 13 98 8 13 AM 2 1 Figure 4 21 Installing a SCSI drive SCSI ID Numbers There are several possible numbering schemes depending on whether you are using 1 inch height...

Страница 88: ...channel simplex mode with 1 6 inch drives Integrated Management Device The Integrated Management Device IMD is standard on all ProLiant 5500 rack mountable models The IMD may be purchased separately a...

Страница 89: ...ndability and supportability To use the SmartStart and Support Software CD refer to the Server Setup and Management pack The first time the server is configured the SmartStart program automatically cr...

Страница 90: ...abel facing up handling the CD from the edges not by the flat surfaces of the disc 4 Close the tray by again pressing the load unload button Upon closing the CD tray the SmartStart installation sequen...

Страница 91: ...ves Sets and stores power on features such as date and time Stores configuration information in non volatile memory Assists in the installation of the operating system Assists in running diagnostic to...

Страница 92: ...You can still configure your server and manually install your operating system SMP Operating System Support Compaq provides optimized software support for the Dual Processing Boards for Microsoft Win...

Страница 93: ...s feature from the System Configuration Utility main menu the utility provides prompts to test inspect upgrade and diagnose the server Diagnostics and Utilities are located on the system partition on...

Страница 94: ...tly at the server to assist the user in diagnosing and servicing the server without using a keyboard and monitor Integrated Management Display Features The features of the Integrated Management Displa...

Страница 95: ...16 PM Installing the IMD in the Tower Model The Integrated Management Display IMD feature is standard in rack mountable models of the Compaq ProLiant servers this feature is optional in tower models T...

Страница 96: ...aq ProLiant 5500 Servers Setup and Installation Guide Comments 328470 001 July 1998 File Name G CH06 DOC Last Saved On 7 6 98 4 16 PM 3 Install the Integrated Management Display 2 1 2 2 2 Figure 6 2 I...

Страница 97: ...ware CD It is recommended that this version of System Configuration be used because it is the latest one that supports the new Integrated Management Display To run the utility 1 Boot the computer from...

Страница 98: ...tegrated Management Display fields are defined later in this chapter 12 In older versions of the System Configuration Utility installed on some hard drives the user will be asked to upgrade its system...

Страница 99: ...name and slogan or goal such as SMITH ASSOC OVER 1 BILLION IN SALES 1997 Custom Menu Item This is a user defined field that can be utilized for customizing each server This one line field can hold up...

Страница 100: ...e entered in this field Administrator Information Name This field contains the name of the system administrator Enter up to 2 lines of no more than 14 characters each Phone Number This field contains...

Страница 101: ...more than 14 characters each Phone Number This field contains the phone number of the service provider Enter up to 2 lines of no more than 14 characters each Pager Number This field contains the page...

Страница 102: ...menu choice enables the user to scroll through a list of all error events starting with the most recent event ROM Date This is the month date year of the current server ROM Bootblock Date This is the...

Страница 103: ...rations is displayed During POST the display indicates the server test in progress by a spinning bar beside the menu item When the test is finished the IMD shows a check mark by the completed menu ite...

Страница 104: ...while scrolling through the menus These symbols are the UP and DOWN arrows and the Selector arrow Table 6 1 Integrated Management Display Symbols Type of Symbol Symbol Meaning Arrow Selector arrow sho...

Страница 105: ...ashes this message ESC ALERT Press Any Key to View New Events LCD 013 EPS Figure 6 5 New event message At this point it is necessary to scroll through each screen of the event information menu before...

Страница 106: ...t Saved On 7 6 98 4 16 PM Menu Structure The following outline shows the structure of each menu and submenu in the order in which it appears Events Event List Administration Information Server Server...

Страница 107: ...d Correctable Error Logs are capable of recording The IML also marks each event with a time stamp with one minute granularity instead of the one hour granularity of the previous logs Events listed in...

Страница 108: ...Compaq SmartStart and Support Software CD Compaq Insight Manager Compaq Insight Manager is a server management tool providing in depth fault configuration and performance monitoring of hundreds of Co...

Страница 109: ...ecovery button 3 Select Integrated Management Log NOTE You can only view the list from the Recovery Integrated Management screen To print the list follow the instructions below 4 If a failed component...

Страница 110: ...the Compaq web site Refer to the Compaq Management CD for information on installing and running the Survey Utility After you have run the Survey Utility you can view the Integrated Management Log by l...

Страница 111: ...r messages Though the same basic information is displayed the format of the list may be different depending on how you are viewing it on the Integrated Management Display from within Compaq Insight Ma...

Страница 112: ...System Fans Not Redundant System Overheating Zone X Location Main Memory Correctable Error threshold exceeded Corrected Memory Error threshold passed Slot X Memory Module X Corrected Memory Error thre...

Страница 113: ...lot X Bus X Device X Function X POST Error POST Error Error message Power Subsystem Power Supply Failure Power Supply Inserted Power Supply Removed Power Supply Not Redundant System Configuration Batt...

Страница 114: ...16 PM Event Messages Continued Event Type Event Message Automatic Server Recovery ASR Reset Detected System Lockup ASR Reset Limit Detected ASR Lockup Detected Cause Operating System System Crash Aut...

Страница 115: ...470 001 July 1998 File Name G CH06 DOC Last Saved On 7 6 98 4 16 PM Error Code Messages Table 6 3 Error Code Messages Error Message Probable Cause Recommended Solution LCD Error 01 Indicates a RAM tes...

Страница 116: ...information is presented for connecting serial ports parallel ports mouse monitor and keyboard ProLiant 5500 Cables Shipped with Server The ProLiant 5500 server is shipped with the following items One...

Страница 117: ...e following illustrations Keep in mind these characteristics All Compaq ProLiant 5500 SCSI connectors are Wide Ultra 68 pin connectors External SCSI cables have a round wire with securable connectors...

Страница 118: ...ProLiant 5500 Servers Setup and Installation Guide Comments 328470 001 File Name H CH07 DOC Last Saved On 7 13 98 11 24 AM External Wide Ultra SCSI Fast Wide SCSI 3 Wide SCSI 68 Pin Internal Wide Ultr...

Страница 119: ...External Cabling The following figure shows the locations of the external connectors on the back of the server 1 2 3 4 6 7 11 12 10 9 8 5 Figure 7 3 External connectors 1 Parallel port connector 7 Hot...

Страница 120: ...3 Identify the controller type 4 Identify the drive type drive cage and expansion slot to be used Wide Ultra SCSI 3 Hard Drive Fast Wide SCSI 2 Hard Drive Fast SCSI 2 Hard Drive Tape Drive SCSI CD ROM...

Страница 121: ...13 98 11 24 AM Integrated SCSI Controller The Compaq ProLiant 5500 server has a Dual Channel Integrated Wide Ultra SCSI 3 controller integrated into the peripheral board The two outputs from this cont...

Страница 122: ...Simplex Configuration Compaq ProLiant 5500 servers are shipped standard in the simplex mode which connects all drives from the hard drive backplane board simplex board to SCSI Port 1 on the peripheral...

Страница 123: ...70 001 File Name H CH07 DOC Last Saved On 7 13 98 11 24 AM SCSI Input 0 Channel The SCSI Input 0 channel connects to SCSI hard drive slots 0 through 6 as shown in Figure 7 6 0 0 1 1 2 2 3 3 4 4 5 5 6...

Страница 124: ...rt 1 Controller Shipping configuration A 19 inch point to point non terminated SCSI cable 199606 007 is connected from SCSI Port 1 to SCSI Input 0 of Simplex board In Simplex mode the recommended use...

Страница 125: ...30 DLT Drive 35 70 DLT Drive Integrated SCSI Port 2 Controller See Note 2 In Simplex mode the recommended use for SCSI PORT 2 is for the removable media bay devices If SCSI PORT 1 is unavailable for t...

Страница 126: ...ch 3 device terminated SCSI cable 199616 012 from optional controller board to removable media bay devices Use 50 to 68 pin adapter 199618 001 if needed See note 1 Use cable option kit part number 306...

Страница 127: ...tch one of these examples use the SCSI Cable Matrices in Tables 7 1 and 7 2 and these examples as a general guide Example 1 Standard Configuration Using Integrated SCSI Port 1 for Hard Drives SCSI Por...

Страница 128: ...ers only Writer Salvo Project Compaq ProLiant 5500 Servers Setup and Installation Guide Comments 328470 001 File Name H CH07 DOC Last Saved On 7 13 98 11 24 AM SCSI Port 1 SCSI Port 2 Peripheral board...

Страница 129: ...ler for Hard Drives Integrated SCSI Port 1 for Removable Media Bay 1 Remove the installed SCSI cable 199606 007 from Integrated SCSI Port 1 and SCSI Input 0 of simplex board 2 Install the 19 inch poin...

Страница 130: ...riter Salvo Project Compaq ProLiant 5500 Servers Setup and Installation Guide Comments 328470 001 File Name H CH07 DOC Last Saved On 7 13 98 11 24 AM SCSI Port 1 SCSI Port 2 Peripheral board Optional...

Страница 131: ...onfigured in the duplex mode split the hard drive backplane board duplex board into two separate independent SCSI channels Each channel supports either 4 X 1 or 3 X 1 6 drives Duplex SCSI Channels In...

Страница 132: ...hannel connects to SCSI hard drive slots 4 through 7 as shown in Figure 7 12 In this case slots 4 through 7 become SCSI IDs 0 through 3 respectively on the SCSI Input 1 channel The SCSI Input 1 channe...

Страница 133: ...board installed on drive cage backplane Controller Hot Plug SCSI Hard Drives in Internal Drive Cage 2 4 DAT Drive 4 8 DAT Drive Internal TurboDAT Autoloader 8X SCSI CD ROM 4 16 TurboDAT 15 30 DLT Driv...

Страница 134: ...Cage 2 4 DAT Drive 4 8 DAT Drive Internal TurboDAT Autoloader 8X SCSI CD ROM 4 16 TurboDAT 15 30 DLT Drive 35 70 DLT Drive Integrated Controller Port 2 See Note 5 Connect 19 inch point to point non te...

Страница 135: ...306585 B21 Connect 19 inch point to point non terminated SCSI cable 199606 007 from optional controller board to SCSI Input 0 of duplex board Connect a second 19 inch point to point non terminated SC...

Страница 136: ...Use cable option kit 306585 B21 Connect 19 inch point to point non terminated SCSI cable 199606 007 from optional controller board to SCSI Input 0 of duplex board or Use second SMART or Smart Array 3...

Страница 137: ...se cable option kit 306585 B21 This kit includes the loop back SCSI cable kit and a SCSI slot bracket Connect 19 inch point to point non terminated SCSI cable 199606 007 from the internal SCSI connect...

Страница 138: ...not operate at ultra SCSI speed if non ultra drives are used in the removable media bay Note 3 If additional external 50 to 68 pin adapters are needed order option kit 212055 001 Note 4 The loopback...

Страница 139: ...f the Drive Cage if not already installed 2 Connect 19 inch point to point non terminated SCSI cable 199606 007 from the SCSI Port 1 to SCSI Input 0 of the duplex board Connect another 19 inch point t...

Страница 140: ...alvo Project Compaq ProLiant 5500 Servers Setup and Installation Guide Comments 328470 001 File Name H CH07 DOC Last Saved On 7 13 98 11 24 AM SCSI Port 1 SCSI Port 2 Peripheral board System board SCS...

Страница 141: ...puters The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user The rating label on the de...

Страница 142: ...States Only This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any i...

Страница 143: ...hoods in order to maintain compliance with FCC Rules and Regulations Canadian Notice Avis Canadien Class B Equipment This Class B digital apparatus meets all requirements of the Canadian Interference...

Страница 144: ...aser product The product does not emit hazardous light the beam is totally enclosed during all modes of customer operation and maintenance Laser Safety Warnings WARNING To reduce the risk of fire bodi...

Страница 145: ...a laser device installed in your product Laser Information Laser Type Semiconductor GaAIAs Wave Length 780 nm 35 nm Divergence Angle 53 5 degrees 0 5 degrees Output Power Less than 0 2 mW 10 869 W m...

Страница 146: ...to forward them to recycling or proper disposal please use the public collection system or return them to Compaq your authorized Compaq Partners or their agents WARNING To reduce the risk of personal...

Страница 147: ...s Keep electrostatic sensitive parts in their containers until they arrive at static free workstations Place parts on a grounded surface before removing them from their containers Avoid touching pins...

Страница 148: ...stallation Guide Comments 328470 001 July 1998 File Name J APPB DOC Last Saved On 7 6 98 12 55 PM If you do not have any of the suggested equipment for proper grounding have an Authorized Compaq Resel...

Страница 149: ...ts of the country where you use the server For more information on power cord set requirements contact your Authorized Compaq Dealer General Requirements The requirements listed below are applicable t...

Страница 150: ...Last Saved On 7 6 98 12 55 PM Country Specific Requirements Use the following table to identify the appropriate accredited agency in your country Table C 1 Power Cord Set Requirements By Country Coun...

Страница 151: ...ible cord must be HAR Type HO5VV F 3 conductor 1 0 mm2 conductor size Power cord set fittings appliance coupler and wall plug must bear the certification mark of the agency responsible for evaluation...

Страница 152: ...ck rail assembly 3 9 bracket cable management arm 3 21 Buttons IMD 6 10 C Cable management arm attaching to bracket 3 24 bracket for 3 21 cables connectors 7 2 determining needs 7 5 SCSI examples 7 12...

Страница 153: ...anagement Display 6 4 Connectors cable 7 2 drive cage 4 19 Fast Wide SCSI 2 68 pin illustrtated 7 2 SCSI input 4 19 7 7 7 16 internal 7 7 7 16 Contrast 6 10 controller SCSI outputs illustrated 7 6 Cus...

Страница 154: ...ll text search ix G Getting Help xviii Grounding Methods B 1 H Hard disk space documentation reader requirements x hard drive 7 5 slots 7 8 Hard drives configuration 1 11 general 1 2 Pre Failure Warra...

Страница 155: ...Pentium II Xeon Processor installing in ProLiant 5500 4 6 Interlock error using LEDs to identify 1 12 4 15 Interlock system identifying board interlocks 1 11 4 15 LEDs as error indicator 1 11 1 12 4 1...

Страница 156: ...field 6 9 Processor Power Module installing next to processor 4 4 program group created x xi ProLiant 5500 weight 3 22 R Rack attaching server rail to server 3 20 Rack Continued cable management arm...

Страница 157: ...rt 2 7 6 simplex mode 7 7 storage capacity 1 11 support 1 3 7 6 wide ultra 7 5 Searching links xiii Security features 1 8 Selector arrow IMD 6 11 Server Health Logs 1 5 management and configuration 1...

Страница 158: ...5 3 starting SmartStart from 2 6 2 7 system partition 5 1 T tape drive 7 5 technotes ix Telephone Numbers xviii temperature requirements recommendations for rack mounted models 2 4 Template Measuring...

Страница 159: ...based servers only Writer Salvo Project Compaq ProLiant 5500 Servers Setup and Installation Guide Comments File Name L INDEX DOC Last Saved On 7 6 98 4 53 PM Windows 3 1 Installing xi Windows 95 Insta...

Отзывы: