4-56
Compaq ProLiant CL380 User Guide
Compaq Confidential – Need to Know Required
Writer:
Marcello Frau
Project:
Compaq ProLiant CL380 User Guide
Comments:
Part Number:
118128-003
File Name:
e-ch4 Installing Hardware Options.doc
Last Saved On:
8/28/00 4:41 PM
Removable Media Devices
NOTE:
Setting SCSI IDs is only necessary for tape drives and non hot-pluggable SCSI
drives. Hard drives in the ProLiant CL380 automatically have the IDs set on the back
plane.
Refer to the general installation guidelines below for general rules regarding
removable media installation.
IMPORTANT:
Compaq recommends that both server nodes be configured identically.
When adding SCSI devices to the server node, observe the following
guidelines:
■
A maximum of 14 SCSI devices per controller can be added.
■
Each SCSI device must have a unique ID. SCSI IDs are automatically
set to 0 and 1 for the hot-plug boot drive cage. Please see Appendix H
“SCSI ID Configurations” for more information.
■
Compaq SCSI cables for the ProLiant CL380 are terminated. Be sure to
remove all terminating jumpers from third-party SCSI devices.
■
Supported Compaq SCSI options are not terminated.
NOTE:
SCSI IDs 6 and 7 are reserved for controllers.
The following table provides the SCSI ID jumper settings for
Compaq SCSI devices.
Table 4-8
SCSI ID Settings
SCSI ID
Bit 2
Bit 1
Bit 0
0
Off
Off
Off
1
Off
Off
On
2
Off
On
Off
3
Off
On
On
4
On
Off
Off
5
On
Off
On
6
On
On
Off