IE-GPR-LP040-03
34
The information that the alarm is active and information about correct operation of the data
logger can be periodically taken (according to the item
Check alarm status
) from the data logger by
the modem. These information are processed and then the modem sends alarm SMS messages to a
customer according to these analyses. If you require sending of the warning SMS messages by the
modem, you will have to tick off the field
Send warning SMS
and enter the phone numbers for the
warning SMS messages recipients.
Attention!
Sending of warning SMS messages from the modem can be temporarily
suspended during the executing of some operations, which involve data transfers
between the data logger, modem and remote computer (e.g. downloading data from a
data logger). In such cases, the SMS messages are stored in a queue and are sent after the
operation is finished.
After pressing
Apply
button, all settings are stored into the modem and then the modem will
be restarted. Confirm all opened windows with pressing
OK
button.