20
MACHINE PREPARATION
To connect the battery charger you must:
1.
Move the machine near to the battery charger
2.
Make sure that the key switch in the “0” position
3.
Engage the parking brake
4.
Grip the handle at the side of the seat to raise the seat mounting plate
5.
Disconnect the electrical system connector (1) from the battery connector (2)
6.
Connecting the battery charger cable connector
The coupling connector of the battery charger is supplied inside the bag containing this instruction booklet,
and must be fitted to the battery charger cables as shown in the instructions.
ATTENTION: this process must be carried out by qualified personnel.
Incorrect connection of the connector may cause machine malfunctions.
7.
Connect the rewired cable to the external battery charger
8.
After the charging cycle is complete, the battery connector (2) must be reconnected to the electrical
system connector (1)
ATTENTION: Carefully read the use and maintenance instructions of the
battery charger that is used for charging.
WARNING: Keep the seat mounting plate raised for the whole duration of the
battery recharging cycle to allow gas fumes to escape
ATTENTION: danger of exhalation of gas and leakage of corrosive liquids
ATTENTION: danger of fire: do not go near with free flames
15.
BATTERY CHARGE LEVEL INDICATOR
On the instrument panel of the machine there is a monitor (1) indicating (amongst other things) the battery
charge status. If the upper line contains 8 light indicators, the battery charge level is 100%. If the edges of
the indicators are flashing, this means the batteries are run down.
ATTENTION: a few seconds after the last indicator on the monitor has
flashed, the brush motor will automatically switch off. With the remaining
charge it is possible to complete the drying process before recharging
1